3
LIGHT CONTROL MODULE OPERATION
The green lights on the option board will turn on if the board is
seated properly and the power is on. When the door reaches the
full open position or programmed mid-stop, the timer circuit will
be activated. The green lamp holder will receive power. If the
timer has not been set, the red lamp holder will receive power
when the door starts to close and until close limit is activated. If
the timer has been set, the red lamp holder will receive power as
indicated by the chart below.
NOTE:
A) The green lamp holder will never receive power if the timer is
set to ten seconds or less. The red lamp holder will blink for one
second on and one second off whenever the door is moving,
even if the timer to close has not been programmed.
B) The 24 Vdc output is for the addition of an optional Horn/
Strobe. When the operator is running OPEN or CLOSE and the
RED warning light is flashing, the output will activate the Horn/
Strobe.
TIMER SETTING
RED LAMP HOLDER
RECEIVES POWER
Greater than or equal to
10 seconds
10 seconds before door starts to
close and until close limit is
activated
Less than 10 seconds
Immediately after reaching open
limit or mid-stop
Wiring Mode
Up Mid-Stop
Down Mid-Stop
B2, C2, E2
Stop movement, wait for user input:
3-Button Control Station will OPEN or
CLOSE on command Single Button
Control/Radio will OPEN on command.
Down Mid-Stop disabled
D1
Up Mid-Stop disabled
Down Mid-Stop disabled
T, TS, FSTS
Stop movement, wait for user input:
3-Button Control Station will OPEN or
CLOSE on command Single Button
Control/Radio will OPEN on command. If
timer to close set is set for up Mid-Stop,
timer to close will close the door
Stop movement, then count down timer to close timer & auto
close
OR
User input during timer to close countdown:
3-Button Control Station will OPEN the door, CLOSE the door, or
STOP the countdown
Single Button Control will CLOSE on command
Radio will OPEN on command
Red/Green enabled at Mid-Stop
Failsafe B2, Failsafe C2 Stop movement, wait for user input:
3-Button Control Station will OPEN or
CLOSE on command
Single Button Control/Radio will OPEN
open command
Down Mid-Stop disabled
Failsafe D1
Up Mid-Stop disabled
Down Mid-Stop disabled
Failsafe E2
Stop movement, wait for user input:
3-Button Control Station will OPEN or
CLOSE on command
Down Mid-Stop disabled