16
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing
door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out
of reach of children at a minimum height of 5 feet
(1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to
door travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of
closing garage door.
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, and away from moving parts of door and door
hardware.
1. Strip 1/4" of insulation from one end of bell wire and
connect to the two screw terminals on back of door
control by color: white wire to 2 and white/red wire to
the 1.
2. Fasten the lighted door control button securely with
6ABx1" screws. If installing into drywall, drill 5/32"
holes and use the anchors provided.
3. Run bell wire up wall and across ceiling to motor unit.
Use insulated staples to secure wire in several places.
Do not pierce wire with a staple, creating a short or
open circuit.
4. Strip 1/4" of insulation from end of bell wire. Connect
bell wire to the quick-connect terminals as follows:
white to white and white/red to red.
NOTE:
When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
5. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.
NOTE:
DO NOT connect the power and operate the opener
at this time. The trolley will travel to the full open position
but will not return to the close position until the sensor
beam is connected and properly aligned.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1"
Drywall Anchors
Insulated Staples
(not shown)
To release or insert
wire, push in tab with
screwdriver tip
Antenna
Lighted Door
Control Button
Terminal
Screws
Lighted Door
Control Button
Bell Wire
Bell Wire
Back Panel
Door Control
Connections
Strip wire 7/16”
Grey
White
Red
7/16"