33
HAVING A PROBLEM?
1.
My door will not close and the light bulbs blink on
my motor unit:
The safety reversing sensor must be
connected and aligned correctly before the garage door
opener will move in the down direction.
•
Verify the safety sensors are properly installed,
aligned and free of any obstructions. Refer to
Installation Step 4: Install The Protector System
®
.
•
Check diagnostic LED for flashes on the motor unit
then refer to the
Diagnostic Chart
on the following
page.
2.
My remotes will not activate the door:
•
Verify your Motion Detecting Door Control is not
blinking. If it is blinking, deactivate the Lock Mode
following the instructions for
Using the Motion
Detecting Door Control.
•
Reprogram remotes following the programming
instructions. Refer to
Programming
.
•
If remote will still not activate your door, check
diagnostic LED for flashes on motor unit then refer to
Diagnostic Chart
on the following page.
3. My door reverses for no apparent reason:
Repeat
safety reverse test after adjustments to force or travel
limits. The need for occasional adjustment for the force
and limit settings is normal. Weather conditions in
particular can affect door travel.
•
Manually check door for balance or any binding
problems.
•
Refer
to
Adjustment Step 2, Setting the Force.
Receiving Eye Safety Reversing
Sensor (Green Indicator Light)
Sending Eye Safety Reversing
Sensor (Amber Indicator Light)
Safety Reversing Sensor
Diagnostics
Located On
Motor Unit
“Learn”
Button LED
or Diagnostic
LED
“Learn” Button
THE REMOTE CONTROL BATTERY
The lithium battery should
produce power for up to 5 years.
To replace battery, use the visor
clip or screwdriver blade to pry
open the case as shown. Insert
battery positive side up (+).
Dispose of old battery properly.
Replace the battery with only
3V2032 coin cell batteries.
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• Do NOT recharge, disassemble, heat above 100°C (212°F) or
incinerate.
Battery
positive
side up (+)
4. My door reverses for no apparent reason after fully
closing and touching the floor:
Repeat safety reverse
test after adjustments to force or travel limits. The need
for occasional adjustment for the force and limit settings
is normal. Weather conditions in particular can affect
door travel.
•
Refer to
Adjustment Step 1, Program the Travel Limits.
5. My lights will not turn off when door is open:
•
The garage door opener is equipped with a security
light feature. This feature activates the light on when
the safety sensor beam has been obstructed. Refer to
Operation section; Using the
Wall Mounted Door
Control, Light Feature.
6. If battery status LED is not lit properly:
• Check battery connections.