CODE SETUP 

The unit’s Master Code is for owner/administrator level commands. The User Codes allow users 
to activate and latch relays 1 and 2.

NOTE: 

The User Code cannot be the same as the Master Code.

PROGRAMMING 

» KEYPAD

TRIGGER RELAY 1 (ONLY)

Enter the Master Code: 

?

 

?

 

?

 

?

NOTE: 

Requires Relay 2 be in Independent Mode.

ENABLE VACATION (LOCK DOWN) MODE

Locks the unit from all User Code activity.

1. Enter the Master Code: 

?

 

?

 

?

 

?

2. Enter the Program Code: 

5

 

2

 

DISABLE VACATION (LOCK DOWN) MODE

1. Enter the Master Code: 

?

 

?

 

?

 

?

2. Enter the Program Code: 

5

 

3

 

TRIGGER RELAY 2

1.  Enter the Master Code: 

?

 

?

 

?

 

?

2. Enter the Program Code: 

2

CODE OPERATION

MASTER CODE OPERATIONS

TRIGGER PROGRAMMED RELAY FOR USER CODE

Enter the User Code: 

?

 

?

 

?

 

?

The Relay will activate.

USER CODE OPERATIONS

ENTER A TEMPORARY (1 SHOT) USER CODE NUMBER

The unit holds 1 temporary User Code.

1. Enter the Master Code: 

?

 

?

 

?

 

?

2. Enter the Program Code: 

5

 

1

 The unit will beep.

3. Enter the Temporary User Code: 

 

 

 

4.  Enter the Relay for the Code to control: 

1

 or 

2

 or no 

button is pressed.

NOTE:

 If no button is pressed in step 4, both relays will 

activate simultaneously. Expires in 24 hours or after 
fi rst use.

ENGAGE PARTY MODE (RELAY 1)

Party Mode will latch relay.

1. Enter the Master Code: 

?

 

?

 

?

 

?

2. Enter the Program Code: 

5

 

4

To disengage party mode: Enter a valid code into the keypad 
or enter “*9” into the local telephone.

ENGAGE PARTY MODE (RELAY 2)

Party Mode will latch relay.

1. Enter the Master Code: 

?

 

?

 

?

 

?

2. Enter the Program Code: 

5

 

6

To disengage party mode: Enter a valid code into the keypad 
or enter “*5” into the local telephone.

NOTE: 

Relay 2 must be in Independent Control Mode to 

engage Party Mode on relay 2. See page 2.

ENTER A USER CODE NUMBERS

1.  Enter the Master Code: 

?

 

?

 

?

 

?

 The unit 

will beep.

2. Enter the Program Code: 

9

 The unit will beep.

3. Enter New User Code: 

 

 

 

 

4.  Enter the Relay for the Code to control: 

1

 or 

2

 or no 

button is pressed.

NOTE: 

If no button is pressed in step 4, both relays will 

activate simultaneously.

DELETE USER CODE NUMBERS

1.  Enter the Master Code: 

?

 

?

 

?

 

?

 The unit will 

beep.

2.  Enter the Program Code: 

7

 The unit will beep.

3.  Enter User Code to be deleted: 

 

 

 

1.  Enter the Master Code: 

?

 

?

 

?

 

?

2. Enter the Program Code: 

1

TRIGGER RELAY 1

Summary of Contents for LiftMaster TAC2C

Page 1: ... 2 3 4 5 6 7 8 9 0 The Chamberlain Group 845 Larch Ave Elmhurst IL 60126 1196 www liftmaster com TAC2C TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL DOORKING 1812 SYSTEMS Programming Guide 1 2 3 4 5 6 7 8 9 0 ...

Page 2: ...e visitor to hear the resident at the unit 1 Low 2 Medium and 3 High Default level is 2 1 Enter the Master Code 2 Enter the Program Code 0 6 3 Enter the Volume Level 1 or 2 or 3 ADJUST RELAY OUTPUT TIME RELAY 1 The amount of time in seconds the relay remains active Default level is 0 5 seconds 1 Enter the Master Code 2 Enter the Program Code 0 2 4 3 Enter the Output Time in seconds Example 0000 0 ...

Page 3: ...ol 1 or 2 or no button is pressed NOTE If no button is pressed in step 4 both relays will activate simultaneously Expires in 24 hours or after first use ENGAGE PARTY MODE RELAY 1 Party Mode will latch relay 1 Enter the Master Code 2 Enter the Program Code 5 4 To disengage party mode Enter a valid code into the keypad or enter 9 into the local telephone ENGAGE PARTY MODE RELAY 2 Party Mode will latc...

Page 4: ...L FORWARDING NUMBER VIA CALLER ID Enter the command tone 0 6 Hang up the phone Wait for the ring Up to a 14 Digit Telco Number ENTER CALL FORWARDING TELEPHONE NUMBER Enter the command tone CALL FORWARDING TELEPHONE COMMANDS TRIGGER RELAY 1 Enter the command tone 9 TRIGGER RELAY 1 Enter the command tone 9 TRIGGER RELAY 2 Enter the command tone 5 TRIGGER RELAY 2 Enter the command tone 5 DISABLE DO N...

Page 5: ... Medium or 3 High 07 Microphone Sensitivity Level 2 Master Code 4 digits 07 Volume Level 1 Low 2 Medium or 3 High 09 Change the Master Code Master Code 4 digits 09 New Master Code 4 digits 51 Create Temporary 1 Shot Code Master Code 4 digits 51 New Temporary 1 Shot Code 4 digits Relay Associated with the User Code 1 or 2 Expires after 24 hours 52 Enable Vacation Lock Down Mode Disabled Master Code...

Page 6: ...able Telco Mode Disabled 07 8 Erase Call Forwarding Number 8 10 Adjust Ring Count 10 Ring Count 2 5 13 Enable Alternate DTMF Programming Disabled 13 14 Enable Standard Long Ring Tone 14 15 Enable Alternate Dual Ring Tone Enabled 15 16 Disable Alternate DTMF Programming 16 Call Forwarding Number Enter Call Forwarding Telephone Number Telephone Number Up to 14 digits PROGRAMMING QUICK REFERENCE MAST...

Page 7: ... 1 9 NOTE Use the STAR Key to cancel any input NOTE Keypad commands are to be entered in a single string to result in success indicated by double high success tone Stop and go keystrokes will result in negative tones low single and triple fail tones PROGRAMMING RESIDENT INSTRUCTIONS FOR TAC MODELS Direct commands allow you to control the unit from the resident telephone To use direct commands lift...

Page 8: ... CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE OR INABILITY TO USE THIS PRODUCT IN NO EVENT SHALL SELLER S LIABILITY FOR BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF TH...

Reviews: