3
Prepare Opener
5
For
left hand side
installations
the wire jumper
should be removed
.
Place the Opener in Manual Release mode.
Pull the release cord down and across to engage the
ball into the cup.
The drive forks should now be able to be moved
manually.
NOTE:
To re-engage the opener, pull the release cord
across and up.
For
right hand side
installations
the wire jumper
should be in place
(factory installed).
Set Opener Position (Left or Right hand)
Engaged
Operation Mode
Disengaged
Manual Release Mode
Attaching the Extension Poles (if required)
1. Insert the extension poles into the gear
2. Align the extension pole holes with the gear holes
3. Using the supplied screws secure the extension poles
.