Door Requirements

3

Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket. If the roller door drums are on
the edge of the curtain or are of small diameter additional clearance maybe required. 

If the drums are more than 60mm from the curtain edge or of small diameter extension poles maybe required.

Different drum and bracket types may result in the minimum side room clearance not being possible and extension poles
being required.
Ensure there is a power point near the opener.

Typical side room installation

Minimum side room installation

The maximum allowable door height is 4.5m, maximum allowable curtain area is 12.0m² (door height in metres multiplied by
the width in metres) and maximum allowable door weight is 100kg. 
The Protector System™ (Safety Beams) must be installed if the force at the edge of the closing door force exceeds 400N
(40kgf). Door shaft diameter must not exceed 35mm.

Prepare Door 

4

Disable locks and remove any ropes connected to
garage door.

Complete the following test to ensure your garage door
is balanced and is not sticking or binding:

1. Lift the door about halfway as shown. Release the door. If
balanced, it should stay in place, supported entirely by its
springs.
2. Raise and lower the door to see if there is any sticking or
binding. If your door binds, sticks or is out of balance, call a
trained door systems technician.

Install stop bracket collar

The stop bracket collar should be installed on the 

opposite

end to where the opener will be installed. Fit the stop bracket
hard against the boss of the door drum.
Ensure that the U-bolt holding the door shaft to the door
bracket is tightly secured.

Install weight bar

1. Place the weight bar at the bottom centre of the door and
mark the two hole positions.
2. Drill two 5.5mm holes at the marked positions.
3. Fix the weight bar to the inside of the door with the
supplied 5mm bolts, washers and nuts.

weight bar

stop bracket collar

Summary of Contents for LiftMaster Professional RDO800-series

Page 1: ...ation and operating instructions for rolling door opener Model RDO800 series Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany TEL 49 0 6838 907 250 FAX 49 0 6838 907 179 www liftmas...

Page 2: ...the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be re...

Page 3: ...eeds 400N 40kgf Door shaft diameter must not exceed 35mm Prepare Door 4 Disable locks and remove any ropes connected to garage door Complete the following test to ensure your garage door is balanced a...

Page 4: ...nually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right hand En...

Page 5: ...Remove rope if used 11 Plug opener into nearby power point and switch on power point opener lights should now turn on FOR LEFT HAND SIDE INSTALLATIONS 1 Ensure that the opener position jumper wire co...

Page 6: ...re with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the link on the emergency release cable Adjust rope length so the handle is...

Page 7: ...hich the door will stop when moving up or down Follow the steps below to set the limits Check that the opener is engaged To program the travel limits 1 Press and hold the black button 3 until the oran...

Page 8: ...ant The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate t...

Page 9: ...connect terminal and the white wire to the white quick connect terminal 2 The Protector System Safety Beams Connect both white wires to the white quick connect terminal and both white black wires to...

Page 10: ...rce setting in section 11 12 pages 6 7 Repeat safety reverse test after adjustments 9 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door and...

Page 11: ...g children Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow a...

Page 12: ...arranty will be the purchaser s sole and exclusive remedy and neither Chamberlain nor its affiliates or distributors shall be liable for any incidental or consequential damages for any express or impl...

Page 13: ...llation and operating instructions for rolling door opener Model RDO800GB Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany TEL 49 0 6838 907 250 FAX 49 0 6838 907 179 www liftmaster...

Page 14: ...f the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be r...

Page 15: ...eeds 400N 40kgf Door shaft diameter must not exceed 35mm Prepare Door 4 Disable locks and remove any ropes connected to garage door Complete the following test to ensure your garage door is balanced a...

Page 16: ...rd down until you hear a clicking sound the motor is now ready for operation Note The drive forks may now be positioned into the drum as required For right hand side installations the wire jumper shou...

Page 17: ...Remove rope if used 11 Plug opener into nearby power point and switch on power point opener lights should now turn on FOR LEFT HAND SIDE INSTALLATIONS 1 Ensure that the opener position jumper wire co...

Page 18: ...with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the link on the emergency release cable Adjust rope length so the handle is no...

Page 19: ...hich the door will stop when moving up or down Follow the steps below to set the limits Check that the opener is engaged To program the travel limits 1 Press and hold the black button 3 until the oran...

Page 20: ...ant The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate t...

Page 21: ...connect terminal and the white wire to the white quick connect terminal 2 The Protector System Safety Beams Connect both white wires to the white quick connect terminal and both white black wires to t...

Page 22: ...rce setting in section 11 12 pages 6 7 Repeat safety reverse test after adjustments 9 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door and...

Page 23: ...g children Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow a...

Page 24: ...ranty will be the purchaser s sole and exclusive remedy and neither Chamberlain nor its affiliates or distributors shall be liable for any incidental or consequential damages for any express or implie...

Reviews: