Door Requirements

3

Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket. If the roller door drums are on
the edge of the curtain or are of small diameter additional clearance maybe required. 

If the drums are more than 60mm from the curtain edge or of small diameter extension poles maybe required.

Different drum and bracket types may result in the minimum side room clearance not being possible and extension poles
being required.
Ensure there is a power point near the opener.

Typical side room installation

Minimum side room installation

The maximum allowable door height is 4.5m, maximum allowable curtain area is 12.0m² (door height in metres multiplied by
the width in metres) and maximum allowable door weight is 100kg. 
The Protector System™ (Safety Beams) must be installed if the force at the edge of the closing door force exceeds 400N
(40kgf). Door shaft diameter must not exceed 35mm.

Prepare Door 

4

Disable locks and remove any ropes connected to
garage door.

Complete the following test to ensure your garage door
is balanced and is not sticking or binding:

1. Lift the door about halfway as shown. Release the door. If
balanced, it should stay in place, supported entirely by its
springs.
2. Raise and lower the door to see if there is any sticking or
binding. If your door binds, sticks or is out of balance, call a
trained door systems technician.

Install stop bracket collar

The stop bracket collar should be installed on the 

opposite

end to where the opener will be installed. Fit the stop bracket
hard against the boss of the door drum.
Ensure that the U-bolt holding the door shaft to the door
bracket is tightly secured.

Install weight bar

1. Place the weight bar at the bottom centre of the door and
mark the two hole positions.
2. Drill two 5.5mm holes at the marked positions.
3. Fix the weight bar to the inside of the door with the
supplied 5mm bolts, washers and nuts.

weight bar

stop bracket collar

Summary of Contents for LiftMaster Professional RDO800 Series

Page 1: ...function Electronic limit switch programming Automatic force adjustment Safety system constantly monitors force door reverses immediately if obstructed Meets all current safety standards High security rolling code eliminates code scanning Light goes on automatically and switches off after 2 1 2 minutes Battery backup Slim design to save side room ...

Page 2: ... 760E Outside keylock 1702E Outside quick release 770E Protector system FLA230 Flashing light kit 475E Battery backup system 128LM 2 function wireless wall control Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket If the roller door drums are on the edge of the curtain or are of small diameter additional clearance maybe required If the drums are more than 6...

Page 3: ...lation and operating instructions for rolling door opener Model RDO800 series Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany TEL 49 0 6838 907 250 FAX 49 0 6838 907 179 www liftmaster com ...

Page 4: ...f the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury Do not wear rings watches or loose clothing while installing or servicing ...

Page 5: ...ceeds 400N 40kgf Door shaft diameter must not exceed 35mm Prepare Door 4 Disable locks and remove any ropes connected to garage door Complete the following test to ensure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door to see if there ...

Page 6: ...anually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right hand Engaged Operation Mode Disengaged Manual Release Mode Attaching the Extension Poles if required 1 Insert the extension poles into the gear 2 Align the extension pole holes with the gear holes 3 Using t...

Page 7: ...0 Remove rope if used 11 Plug opener into nearby power point and switch on power point opener lights should now turn on FOR LEFT HAND SIDE INSTALLATIONS 1 Ensure that the opener position jumper wire connector has been removed refer section 5 page 3 2 Place the opener in manual release mode refer section 5 page 3 3 Open the roller door fully For safety tie a rope around the door 4 Ensure that the U...

Page 8: ...ure with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the link on the emergency release cable Adjust rope length so the handle is no higher than 1 8m above the floor Secure with an overhand knot If the door is greater than 2 5m in height the Release Cord Extension kit accessory is required NOTE If it is necessary to cut the ro...

Page 9: ...which the door will stop when moving up or down Follow the steps below to set the limits Check that the opener is engaged To program the travel limits 1 Press and hold the black button 3 until the orange indicator light 2 starts flashing slowly and then release Opener lights will dim 2 Press the BLACK button to move the door UP or the PURPLE button to move the door DOWN until the door reaches the ...

Page 10: ...tant The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate the door in the down direction The door must reverse on the obstruction If the door stops on the obstruction remove obstruction and repeat limit and force setting sections 11 12 pages 6 7 Repeat test ...

Page 11: ...k connect terminal and the white wire to the white quick connect terminal 2 The Protector System Safety Beams Connect both white wires to the white quick connect terminal and both white black wires to the grey quick connect terminal 3 Flashing light connection The flashing light can be installed anywhere 4 Battery Backup To access the battery backup connector remove the knockout to the right of th...

Page 12: ...orce setting in section 11 12 pages 6 7 Repeat safety reverse test after adjustments 9 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door and use the manual release to disconnect the door Open and close the door manually A properly balanced door will stay in any point of travel while being supported entirely by its springs If it does not d...

Page 13: ...ng children Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious personal injury could result The door can be opened manually by pulling the release cord down and across to engage the ball into the cup To reco...

Page 14: ...warranty will be the purchaser s sole and exclusive remedy and neither Chamberlain nor its affiliates or distributors shall be liable for any incidental or consequential damages for any express or implied warranty relating to this product No representative or person is authorized to assume for Chamberlain any other liability in connection with the sale of this product EDR4 8004A 11 C 2007 Chamberl...