background image

GARAGE DOOR OPENER WARRANTY

Chamberlain warrants to the first retail purchaser of this product
that the product shall be free from any defect in materials and/or
workmanship for a period of 24 full months (2 years) from the
date of purchase. Upon receipt of the product, the first retail
purchaser is under obligation to check the product for any visible
defects. 

Conditions:

The warranty is strictly limited to the reparation or

replacement of the parts of this product which are found to be
defective and does not cover the costs or risks of transportation
of the defective parts or product.

This warranty does not cover non-defect damage caused by
unreasonable use (including use not in complete accordance
with Chamberlain’s instructions for installation, operation and
care; failure to provide necessary maintenance and adjustment;
or any adaptations of or alterations to the products), labor
charges for dismantling or reinstalling of a repaired or replaced
unit or replacement batteries.

A product under warranty which is determined to be defective in
materials and/or workmanship will be repaired or replaced (at
Chamberlain's option) at no cost to the owner for the repair
and/or replacement parts and/or product. Defective parts will be
repaired or replaced with new or factory rebuilt parts at
Chamberlain's option.

If, during the warranty period, the product appears as though it
may be defective, contact your original place of purchase.

This warranty does not affect the purchaser’s statutory rights
under applicable national legislation in force nor the purchaser’s
rights against the retailer arising from their sales/purchase
contract. In the absence of applicable national or EU legislation,
this warranty will be the purchaser’s sole and exclusive remedy,
and neither Chamberlain nor its affiliates or distributors shall be
liable for any incidental or consequential damages for any
express or implied warranty relating to this product.

No representative or person is authorized to assume for
Chamberlain any other liability in connection with the sale of this
product.

EDR4 8004A

11

C

, 2007 Chamberlain

These declarations are made by:

D e c l a r a t i o n   o f   C o n f o r m i t y

Automatic rolling door openers, as stated, are in conformity to the applicable sections of EN55014-1
(2000), EN55014-2 (1997), EN61000-3-2 (2000), EN61000-3-3 (1995), EN 301 489-3 (V1.3.1), 
EN 300 220-3 (V1.1.1), EN60335-1 (1994), and EN60335-2-95 (2000).

Per the provisions of the European Directives, 89/336/EEC, 2006/95/EC and 1999/5/EC, including all
amendments;
Model:..................................................................................................................................RDO800 

All technical file information for the operator and its accessories is held at The Chamberlain Group and
will be made available at the request of the authorities should the need arise

.

D e c l a r a t i o n   o f   I n c o r p o r a t i o n

A power door operator must not be put into service until it has been completely and safely assembled
and installed, with appropriate size and weight of door, in accordance with both the door and operator
manufacturers’ instructions using appropriate safety devices, and the complete installation has been
declared in conformity with the provisions of EN12453, EN13241-1 and the Machinery Directive,
98/37/EC. 

Door Type: Rolling Door

Operator
Type

Maximum Area
(m2)

Installer: Indicate
Installed Door
Size

Maximum Weight
(kg)

Installer: Indicate
Installed Door
Weight

RDO800

12.0

100

B. P. Kelkhoff
Manager, Regulatory Affairs

Chamberlain GmbH.
D-66793 Saarwellingen
June

, 2007

________________________________________

Installer Name/Signature

________________________________________

Company Name

________________________________________

Address

_____________________________________

Date

Summary of Contents for LiftMaster Professional RDO800 Series

Page 1: ...function Electronic limit switch programming Automatic force adjustment Safety system constantly monitors force door reverses immediately if obstructed Meets all current safety standards High security rolling code eliminates code scanning Light goes on automatically and switches off after 2 1 2 minutes Battery backup Slim design to save side room ...

Page 2: ... 760E Outside keylock 1702E Outside quick release 770E Protector system FLA230 Flashing light kit 475E Battery backup system 128LM 2 function wireless wall control Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket If the roller door drums are on the edge of the curtain or are of small diameter additional clearance maybe required If the drums are more than 6...

Page 3: ...lation and operating instructions for rolling door opener Model RDO800 series Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany TEL 49 0 6838 907 250 FAX 49 0 6838 907 179 www liftmaster com ...

Page 4: ...f the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or sticking garage door Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury Do not wear rings watches or loose clothing while installing or servicing ...

Page 5: ...ceeds 400N 40kgf Door shaft diameter must not exceed 35mm Prepare Door 4 Disable locks and remove any ropes connected to garage door Complete the following test to ensure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door to see if there ...

Page 6: ...anually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right hand Engaged Operation Mode Disengaged Manual Release Mode Attaching the Extension Poles if required 1 Insert the extension poles into the gear 2 Align the extension pole holes with the gear holes 3 Using t...

Page 7: ...0 Remove rope if used 11 Plug opener into nearby power point and switch on power point opener lights should now turn on FOR LEFT HAND SIDE INSTALLATIONS 1 Ensure that the opener position jumper wire connector has been removed refer section 5 page 3 2 Place the opener in manual release mode refer section 5 page 3 3 Open the roller door fully For safety tie a rope around the door 4 Ensure that the U...

Page 8: ...ure with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the link on the emergency release cable Adjust rope length so the handle is no higher than 1 8m above the floor Secure with an overhand knot If the door is greater than 2 5m in height the Release Cord Extension kit accessory is required NOTE If it is necessary to cut the ro...

Page 9: ...which the door will stop when moving up or down Follow the steps below to set the limits Check that the opener is engaged To program the travel limits 1 Press and hold the black button 3 until the orange indicator light 2 starts flashing slowly and then release Opener lights will dim 2 Press the BLACK button to move the door UP or the PURPLE button to move the door DOWN until the door reaches the ...

Page 10: ...tant The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate the door in the down direction The door must reverse on the obstruction If the door stops on the obstruction remove obstruction and repeat limit and force setting sections 11 12 pages 6 7 Repeat test ...

Page 11: ...k connect terminal and the white wire to the white quick connect terminal 2 The Protector System Safety Beams Connect both white wires to the white quick connect terminal and both white black wires to the grey quick connect terminal 3 Flashing light connection The flashing light can be installed anywhere 4 Battery Backup To access the battery backup connector remove the knockout to the right of th...

Page 12: ...orce setting in section 11 12 pages 6 7 Repeat safety reverse test after adjustments 9 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door and use the manual release to disconnect the door Open and close the door manually A properly balanced door will stay in any point of travel while being supported entirely by its springs If it does not d...

Page 13: ...ng children Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious personal injury could result The door can be opened manually by pulling the release cord down and across to engage the ball into the cup To reco...

Page 14: ...warranty will be the purchaser s sole and exclusive remedy and neither Chamberlain nor its affiliates or distributors shall be liable for any incidental or consequential damages for any express or implied warranty relating to this product No representative or person is authorized to assume for Chamberlain any other liability in connection with the sale of this product EDR4 8004A 11 C 2007 Chamberl...

Reviews: