WIRING

The LiftMaster CPICARD is used to connect the LC-36A and CPS-OPEN4 to a non-monitored operator. The CPICARD separates the 
incoming and outgoing logic, minimizing interference. The CPICARD accepts both pulsed and normally open contact devices which 
appear to the operator as normally open devices.

Refer to the manual for your specific operator’s wiring diagram.

The chart below shows some compatible non-LiftMaster operators. Refer to the manufacturer’s manual and wiring diagrams before 
installing accessories to any non-LiftMaster operator. 

BRAND

MODEL

EDGE AND COMMON TERMINALS

POWER OUTPUT TERMINALS

DoorLEC Corporation

EHJ 1/2 HP

5-6

9-11

EHJ 1 HP

5-6

9-11

Lynx

MCJH

7-8

1-2

Manaras

OSH 1/2 HP

3-5

1-2

OSH 1 HP

3-5

1-2

Micanan

PRO-HHD

6-7

1-9

Genie

GCL-J & H

Reverse x2

1-3 (Radio Port)

1.  Disconnect power to the operator. 

2.  Connect the EDGE and COMMON terminals on the operator to 

the SENSING EDGE INPUT terminals on the CPICARD.

3.  Connect the black and white wires from the LC-36A receiver 

(Red Cable), to the INFRARED BLACK OR BROWN and 
INFRARED WHITE OR BLUE terminals on the CPICARD 
respectively.

4.  Connect the blue wires from the LC-36A transmitter and 

receiver to the +24V terminal on the CPICARD.

5.  Connect the brown wires from the LC-36A transmitter and 

receiver to the COMMON terminal on the CPICARD.

6.  Connect the wires from the CPS-OPEN4 photoelectric sensors 

to the to the INFRARED BLACK OR BROWN and INFRARED 
WHITE OR BLUE terminals on the CPICARD respectively.

7.  Connect the 24V power output terminals from the operator 

or

 

wires from the 100MAPS external power supply if power from 
operator is not available, to the +24V and COMMON terminals 
on the CPICARD.

8. Reconnect power to the operator. 

9.  Test all entrapment devices to make sure they function 

properly. If an entrapment device does not reverse or stop the 
door when obstructed, check all connections to ensure the 
device is wired correctly.

LiftMaster CPICARD

Blue

Brown

Black

Black

White

Black/White

24VAC or 24VDC

power output

terminals on operator

EDGE and COMMON

terminals on operator

CPS-OPEN4
photoelectric sensors

Receiver
(red cable)

LC-36A
Light Curtain

Transmitter

(black cable)

LiftMaster 100MAPS
external power supply
(if power from operator is not available)