Chamberlain HDFSL24UL Installation Manual Download Page 2

2

SAFETY 2

Safety Symbol and Signal Word Review ................................................2
Usage Class ...........................................................................................3
UL325 Entrapment Protection Requirements ........................................3
Safety Installation Information ...............................................................4
Gate Construction Information ...............................................................5

INTRODUCTION 6

Carton Inventory ....................................................................................6
Operator Specifications ..........................................................................7
Site Preparation .....................................................................................8

INSTALLATION 9

Types of Installations .............................................................................9
Step 1 Determine Location for Operator ..............................................10
Step 2 Install the Operator ...................................................................11
Step 3 Attach the Chain .......................................................................12
Step 4 Install Entrapment Protection ...................................................14
Step 5 Earth Ground Rod .....................................................................16
Step 6 Power Wiring ............................................................................16
Step 7 Connect Batteries .....................................................................18
Step 8 Dual Gate Setup ........................................................................20
Step 9 Install the Cover .......................................................................22
Step 10 Install Warning Signs .............................................................22

ADJUSTMENT 23

Limit, Speed, and Force Adjustment ....................................................23
Obstruction Test ..................................................................................24

PROGRAMMING  

26

Remote Controls (Not Provided) .........................................................26
LiftMaster Internet Gateway (not provided) .........................................27
CAPXL Connected Access Portal .........................................................27
Erase All Codes ....................................................................................28
Erase Limits .........................................................................................28
Constant Pressure Override (CPO) ......................................................28
Gate Hold Open Feature .......................................................................28
To Remove and Erase Monitored Entrapment Protection Devices .......28

OPERATION 29

Gate Operator Setup Examples ............................................................29
Control Board Overview .......................................................................30
Manual Disconnect ..............................................................................31
Reset Switch ........................................................................................31
Relay Board and Terminal Block Access ..............................................31
Operator Alarm ....................................................................................32
Remote Control ....................................................................................32

ACCESSORY WIRING 

33

External Control Devices ......................................................................33
Locks ...................................................................................................34
Miscellaneous Wiring ...........................................................................34

EXPANSION AND RELAY BOARDS 

35

Expansion and Relay Boards Overview ................................................35
Auxiliary Relays ...................................................................................36
Wiring Accessories to the Expansion Board ........................................37

MAINTENANCE 38

Important Safety Instructions ..............................................................38
Maintenance Chart ...............................................................................39
Batteries ...............................................................................................39
Drive Train ...........................................................................................39

TROUBLESHOOTING 40

Diagnostic Codes .................................................................................40
Control Board LEDs .............................................................................41
Troubleshooting Chart .........................................................................42

SOLAR PANELS 

45

Step 6 Solar Panel(s) ...........................................................................45

REPAIR PARTS 

49

ACCESSORIES 50

WARRANTY 52

APPENDIX 53

SAMS Wiring With Relays Not Energized ............................................53
Dual Gate Settings ...............................................................................53
Limit Setup With a Remote Control .....................................................54
Wiring Diagram ....................................................................................55
Diagnostic Codes Table .......................................................................56
Site Planning Safety Checklist .............................................................58

WARNING:

 This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects 

or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov.

When you see these Safety Symbols and Signal Words on the following pages, they will alert 
you to the possibility of 

Serious Injury or Death

 if you do not comply with the warnings that 

accompany them. The hazard may come from something mechanical or from electric shock. 
Read the warnings carefully.

When you see this Signal Word on the following pages, it will alert you to the possibility of 
damage to your gate and/or the gate operator if you do not comply with the cautionary 
statements that accompany it. Read them carefully.

IMPORTANT NOTE:

•  

BEFORE attempting to install, operate or maintain the operator, you must read and fully 
understand this manual and follow all safety instructions.

•   DO NOT attempt repair or service of your gate operator unless you are an Authorized 

Service Technician.

MECHANICAL

ELECTRICAL

TABLE OF CONTENTS

SAFETY

Safety Symbol and Signal Word Review

Summary of Contents for HDFSL24UL

Page 1: ...V vehicular slide gate applications HDFSL24UL is intended for use in Class III and IV vehicular slide gate applications ONLY Visit LiftMaster com to locate a professional installing dealer in your area This gate operator is compatible with MyQ and Security 2 0 accessories LiftMaster 300 Windsor Drive Oak Brook IL 60523 Access installation and technical support guides or register this product Send ...

Page 2: ... 37 MAINTENANCE 38 Important Safety Instructions 38 Maintenance Chart 39 Batteries 39 Drive Train 39 TROUBLESHOOTING 40 Diagnostic Codes 40 Control Board LEDs 41 Troubleshooting Chart 42 SOLAR PANELS 45 Step 6 Solar Panel s 45 REPAIR PARTS 49 ACCESSORIES 50 WARRANTY 52 APPENDIX 53 SAMS Wiring With Relays Not Energized 53 Dual Gate Settings 53 Limit Setup With a Remote Control 54 Wiring Diagram 55 ...

Page 3: ...er devices in the same entrapment zone Use the Site Planning Safety Checklist in the appendix to identify entrapment zones found in your installation Requirements l A minimum of two independent monitored entrapment protection devices are required to be installed at each entrapment zone l It is the responsibility of the installer to install external monitored entrapment protection devices for each ...

Page 4: ...g a Stop and or Reset button it must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start 10 A minimum of two 2 WARNING SIGNS shall be installed in the area of the gate Each warning sign is to be visible by persons located on the side of the gate on which the sign is installed 11 For a gate operator utilizing a non contact sensor a Refer...

Page 5: ...t the existing gate shall be upgraded to conform to the provisions of ASTM F2200 2 4 When the gate of an automated gate system requires replacement the new gate shall conform to the provisions of ASTM F2200 3 Vehicular Horizontal Slide Gates 3 1 The following provisions shall apply to Class I Class II and Class III vehicular horizontal slide gates 3 1 1 All weight bearing exposed rollers 8 feet 2 ...

Page 6: ...er link Eye Bolt Kit LiftMaster Monitored Retro Reflective Photoelectric Sensor Model LMRRUL HDSL24UL only 5 ft Edge sensor kit HDSL24UL 1 HDFSL24UL 2 Key 2 Battery 12 Vdc 7AH 2 Warning Signs 2 Installation Manual Cover Operator MONITORED ENTRAPMENT PROTECTION DEVICES INTRODUCTION ...

Page 7: ...Maximum Gate Travel Distance 75 feet 22 86 m Maximum Gate Travel Speed HDSL24UL 1 ft sec HDFSL24UL 2 ft sec Maximum Daily Cycle Rate Continuous for line voltage not continuous for solar Maximum Duty Cycle Continuous Operating Temperature Without Heater 20 C to 60 C 4 F to 140 F With Optional Heater 40 C to 60 C 40 F to 140 F 120VAC accessory power outlets 6 amps When the 3PHCONV kit is used the ou...

Page 8: ...ASTM F2200 standards refer to page 4 Gate must fit specifications of operator refer to specifications SAFETY CATCH ROLLERS Install catch rollers with safety covers on the side of a post or wall with a minimal distance of half an inch between the rollers and gate DO NOT use a gate catch post Because the coasting distance may vary due to changes in temperature it is NOT recommended to install a catc...

Page 9: ...re than 18 inches 46 cm deep l ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment Types of Installations Standard Installation Gate Rail Stop Operator Inside Property Gate Rail Stop Rear Installation Inside Property Gate Rail Stop Operator Gate Rail Stop INSTALLATION ...

Page 10: ...er conduit Below the frost line Check all national and local codes 6 15 2 cm Above Ground 1 2 1 8 cm 1 2 2 5 5 1 cm Pad conduit location Rear Installation 1 The gate operator should be installed near the back of the gate in the OPEN position Lay out the concrete pad 2 Install the electrical conduit 3 Pour a concrete pad reinforced concrete is required conduit Back of gate Gate in open position Bel...

Reviews: