Remove the control station cover.
Select appropriate knockout and run the wires to the
operator.
1
Connect wires to the control station and replace the control
station cover.
4
3
Fasten the entrapment warning placard next to the control
station.
5
2
Fasten the control station to the wall at least 5 feet (1.5 m)
above the ground.
The installation surface must be smooth
and flat.
Attach the MAS label to the side of the control
station.
CONTROL STATION
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing door
control.
To prevent possible SERIOUS INJURY or DEATH from a closing
door:
• Install door control within sight of door, out of reach of
children at a minimum height of 5 feet (1.5 m) and away from
ALL moving parts of door.
• Install the control station far enough from the door to prevent
the user from coming in contact with the door while operating
the controls.
• Install the entrapment warning placard on wall next to the
control station in a prominent location that is visible from the
door.
• NEVER permit children to operate or play with door control
push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly
adjusted and there are no obstructions to door travel.
• ALWAYS keep door in sight until completely closed. NEVER
permit anyone to cross path of closing door.
ENGLISH WARNINGS AT 50%
SPANISH WARNINGS AT 50%
FRENCH WARNINGS AT 50%
NOTE:
The low voltage control circuit wiring requires insulated, 20
AWG or greater wire. Refer to back page for additional control
wiring.
Wiring
11
3-Button
Station
LED
Maintenance
Alert LED
(WH)
(RD)
Open
Close
Stop
4
^
O
OPEN
ST
OP
^
CLOSE
5’ (1.5 m)
1
2
3
5
UL Entrapment Placard
MAS Label