13
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing
door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet
(1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to
door travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of closing
garage door.
INSTALLATION STEP 6
Install the Control Console
Locate control console within sight of door, at a minimum
height of 5' (1.5 m) where small children cannot reach,
away from moving parts of door and door hardware.
If installing into drywall, drill 5/32" holes and use the
anchors provided. For pre-wired installations (as in new
home construction), it may be mounted to a single gang
box (Figure 1).
CAUTION:
Continuous exposure of the control console to
temperatures below –22° F (–30° C) may damage the LCD
screen.
NOTE:
The functional temperature range of the control
console is between –4° F (–20° C) and 122° F (50° C).
Scroll speed of the display is slower at lower temperatures
although the control console remains fully functional.
SPECIAL NOTE:
Only one 398LMC can be connected to each
garage door opener. If additional wall controls are desired to
operate the same garage door opener, it is recommended to
use model 378LMC wireless wall control as the secondary
control console.
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back
of control console by color: white wire to the W (2)
and white/red wire to the R (1) (Figure 2).
2. Remove push bar cover by gently prying at the lower/
middle portion of the cover with a small fl at-head
screwdriver (Figure 1). Fasten with 6AB x 1-1/4"
self-tapping screws (drywall installation) or 6-32 x 1"
machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of control console on screw head
and slide down to secure. Adjust screw for snug fi t.
• Drill and install top screw with care to avoid cracking
plastic housing.
DO NOT overtighten
.
• Replace cover by inserting top tabs fi rst and then
snap cover in place (Figure 1).
3.
(For standard installations ONLY)
Run bell wire up
wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. DO NOT pierce
wire with a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals on the
motor unit: white to white and white/red to red
(Figure 3).
NOTE:
If you have any trouble with the operation of the
buttons, loosen the top mounting screw. DO NOT connect
the power and operate the opener at this time. The trolley
will travel to the full open position but will not return to
the close position until the sensor beam is connected and
properly aligned.
Figure 2
Figure 1
Figure 3
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/4"
(Std Installation)
Drywall Anchors
Insulated Staples
Screw 6-32x1" (pre-wired)
24 Volt Bell Wire
Push Bar Cover
Push Bar
Light Button
Lock
Button
2-Conductor
Bell Wire
Door
Control
Terminal
Screws
(BACK VIEW)
1
3
9
7
5
1
3
9
7
5
To release or insert
wire, push in tab
with screwdriver tip
Red
7/16 (11 mm)
Strip wire 7/16" (11 mm)
Grey
White
Door Control
Connections
To Replace Insert
Top Tabs First
REMOVE COVER
PRE-WIRED INSTALLATION
REPLACE COVER
Summary of Contents for Elite 3585CS