WIRING DIAGRAMS
WIRING TABLE CSW200UL8™ AND CSW200ULDM8™
OmniControl™ Board
J #
J Pin #
Signal Type
Direction
Level (+/- 10%)
Input Connection
J1
1
2
3
4
5
6
7
8
9
10
Safety Loop
Input Power Neutral
Center Loop
Input Power 120 Vac
Strike Open
Exit Loop
Radio Receiver –
Radio Receiver
Fire Dept Key Switch
Radio Re
In
In
In
In
In
In
In
In
In
Out
5 or 0 Vdc
0V
5 or 0 Vdc
120 Vac
5 or 0 Vdc
5 or 0 Vdc
0V
0V
Dry
24 Vdc
External Loop Detector Wires, 120 Vac
Power, Radio Receiver, Strike Open, Key
Switch Harness
J2
10 Pins
OmniControl™ Option Board
Out
24 Vdc
OmniControl™ Board Input
J3
1
2
3
4
5
6
7
8
9
10
Limit Switch Red N.O.
Motor White
Normally Closed (No Wire)
Motor Black
Limit Switch Brown Com
Motor Green
Purple Com
Blue N.O.
Limit Switch Yellow Com
Limit Switch Orange N.O.
Out
Out
In
Out
In
Out
In
In
In
In
0 Vdc
0V
5 or 0 Vdc
120 Vac
0V
120 Vac
0V
5 or 0 Vdc
0V
5 or 0 Vdc
Motor(s), Limit Switches,
Maglock/Solenoid Harness
J5
1
2
3
4
5-7
–
Reset Switch Red
–
Reset Switch Black
–
In
In
In
In
In
–
Dry
–
Dry
–
Reset Switch Input
J6
1
2
3
4
UL Alarm Red
UL Alarm Black
Photoelectric Sensor
Photoelectric Sensor
Out
Out
In
In
24 Vdc
0 Vdc
5 or 0 Vdc
0V
UL Alarm and Photoelectric Sensors
J7
1
2
3
Relay Adapter Red
Relay Adapter White
Relay Adapter Black
In
In
In
5 or 0 Vdc
0 Vdc
0 Vdc
Relay Adapter Module Input
J8
1-2
3-4
5-6
Plug-In Exit Loop Wire
Plug-In Safety Loop Wire
Plug-In Center Loop Wire
In
In
In
2 to 10 Vdc
2 to 10 Vdc
2 to 10 Vdc
Plug-In Loop Detector Wires
J9
16 Pins
1 HP Board
–
–
Not Used
J10
1
2
3
G M/S Link
B M/S Link
A M/S Link
In/Out
In/Out
In/Out
0 Vdc
5 or 0 Vdc
5 or 0 Vdc
Primary/Secondary Link
J11
10 Pins
Center Loop Detector
In
5 or 0 Vdc
Plug-In Loop Detector Inputs
J12
10 Pins
Safety Loop Detector
In
5 or 0 Vdc
J13
10 Pins
Exit Loop Detector
In
5 or 0 Vdc
OmniControl™ Surge Suppressor
J1
1
2
3
G M/S Link (G)
B M/S Link (B)
A M/S Link (A)
In/Out
In/Out
In/Out
0V
5 or 0 Vdc
5 or 0 Vdc
Primary/Secondary Link Input
J2
1
2
3
4
5
6
7
Fire Dept. Key Switch (7)
Fire Dept. Key Switch (8)
Strike Open Push Button (9)
Strike Open Push Button (10)
Radio Receiver – (11)
Radio Receiver (12)
Radio Re (13)
In
In
In
In
In
In
Out
Dry
Dry
5 or 0 Vdc
0V
0V
5 or 0 Vdc
24 Vdc
Radio Receiver, Strike Open Push Button,
Fire Dept Key Switch Inputs
J3
1-2
3-4
5-6
Center External Loop Detector
Safety External Loop Detector
Exit External Loop Detector
In
In
In
2 to 10 Vdc
2 to 10 Vdc
2 to 10 Vdc
External Loop Detector Center, Safety, Exit