31
Adjust the “
Reverse Sensor
” on the OmniControl™ board.
Alarm Sensor does not need to be adjusted except where noted below.
The level of reverse sensitivity depends on the weight of the gate and the condition of installation.
Sensor is too sensitive
= If the gate stops in mid cycle or reverses by itself.
Sensor is not sensitive enough
= If the gate hits an object and does not stop or reverse.
Maximum
Sensitivity
Maximum
Sensitivity
Minimum
Sensitivity
Minimum
Sensitivity
DC2000™ Reverse Sensor
The DC2000™ has a separate reverse sensor that will need to be
adjusted. The 120 Vac operator power needs to be turned off and
the DC2000™ should have the “
Charge OK
” LED
ON
to make the
adjustment.
ADJUSTING REVERSING SENSOR(S)