background image

1

To prevent possible SERIOUS INJURY or DEATH from electrocution:

•   Be sure power is NOT connected BEFORE installing door control.

•   Connect ONLY to 24 VOLT low voltage wires. 

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

•   Install door control within sight of garage door, out of reach of children at a minimum 

height of 5 feet (1.5 m), and away from ALL moving parts of door.

•   NEVER permit children to operate or play with door control push buttons or remote control 

transmitters.

•   Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no 

obstructions to door travel.

•   ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross 

path of closing garage door.

PREMIUM MOTION-DETECTING CONTROL PANEL

Models 935EV, 935EVC and 41A7327-1

® 

Feature Overview

TIMER-TO-CLOSE (TTC) FOR MODEL 41A7327-1 ONLY

DO NOT enable TTC if operating a one-piece door. TTC is to be used ONLY with sectional doors. 
The TTC can be set to automatically close your garage door after a specified period of time (1, 5, 
or 10 minute intervals). The garage door opener will beep and the lights will fl ash before closing 
the door. TTC WILL NOT work if the garage door opener is operating by battery power or if the 
safety reversing sensors are misaligned. This feature is NOT intended to be the primary method of 
closing the door. 

A keyless entry should be installed in the event of an accidental lock out when 

using this feature.

Premium Motion-Detecting 

Control Panel

Safety Reversing 
Sensors

Yellow 
LEARN Button

NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifi cations of this receiver and/or transmitter are 
prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards for Home or offi ce use. Operation is subject to the following two conditions: (1) this device may not 
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired 
operation.

This Class B digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

For use with MyQ™ Garage Door Openers. The features are adjustable and may be turned off or on 
as desired. Refer to the Feature Settings section.

LOCK

The LOCK feature is designed to prevent activation of the garage door opener from remote 
controls while still allowing activation from the door control and keyless entry. This feature is 
useful for added peace of mind when the home is empty (i.e. vacation).

MOTION SENSOR

The motion sensor will automatically turn on the garage door opener lights when motion is 
detected. The lights will come on for the set period of time, then shut off. The factory setting is on 
and set at 4-1/2 minutes.

LIGHT BUTTON

Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned 
on they will stay on until the LIGHT button is pressed again, or until the garage door opener is 
activated. Once the garage door opener is activated the lights will turn off after the specified period 
of time (the factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the 
door is in motion.

Summary of Contents for 935EV

Page 1: ... Button NOTICE To comply with FCC and or Industry Canada rules IC adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards for Home or office use Operation is subject to the following two conditions 1 this device may not cause harmful inter...

Page 2: ... 4 mm hole Install the bottom screw allowing 1 8 3 mm to protrude from the wall Position the bottom hole of the door control over the screw and slide down into place Lift the push bar up and mark the top hole Remove the door control from the wall and drill a 5 32 4 mm hole for the top screw Position the bottom hole of the door control over the screw and slide down into place Attach the top screw W...

Page 3: ... LED TIMER TO CLOSE TTC FOR MODEL 41A7327 1 ONLY DO NOT enable TTC if operating a one piece door TTC is to be used ONLY with sectional doors The TTC can be turned on or off and the time interval can be adjusted to 1 5 and 10 minute intervals Once the TTC has been set and the door is open the selected close interval will blink and begin to count down to close the door The garage door opener will be...

Page 4: ...irmation Deactivate Press and hold the OFF button until all TTC LEDs turn off and a beep is heard from the motor unit Temporarily hold door open suspend TTC Press and release the HOLD OPEN button Press the HOLD OPEN button again to resume normal TTC operation ON Button OFF Button HOLD OPEN Button 1 Minute TTC LED 5 Minute TTC LED 10 Minute TTC LED NOTE DO NOT enable TTC if operating a one piece do...

Reviews: