43
Troubleshooting
Diagnostic Chart
Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage door opener flash the diagnostic codes.
DIAGNOSTIC CODE
SYMPTOM
SOLUTION
Up Arrow Flash(es)
Down Arrow Flash(es)
1
1
The garage door opener will not close.
Safety reversing sensors are not installed, connected, or wires may be cut. Inspect sensor wires for
a disconnected or cut wire.
1
2
The garage door opener will not close.
There is a short or reversed wire for the safety reversing sensors. Inspect safety sensor wire at all
staple and connection points, replace wire or correct as needed.
1
3
The door control will not function.
The wires for the door control are shorted or the door control is faulty. Inspect door control wires
at all staple and connection points, replace wire or correct as needed.
1
4
The garage door opener will not close.
Safety reversing sensors are misaligned or were momentarily obstructed. Realign both sensors
until both LEDs are glowing steady. Make sure nothing is hanging or mounted on the door that
would interrupt the sensor’s path while closing.
1
5
Door moves 6-8" (15-20 cm) stops or reverses.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or
door lock, correct as needed. Check wiring connections at travel module and at the logic board.
Replace travel module if necessary.
No movement, only a single click.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or
door lock, correct as needed. Replace logic board if necessary.
Opener hums for 1-2 seconds no movement.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or
door lock, correct as needed. Replace motor if necessary.
1
6
Door coasts after it has come to a complete stop.
Program travel to coasting position or have door balanced by a trained door systems technician.
2
1-5
No movement, or sound.
Replace logic board.
3
2
Unable to set the travel or retain position.
Check travel module for proper assembly, replace if necessary.
3
3
The battery status LED is constantly flashing green.*
Battery backup charging circuit error, replace the logic board. *(if applicable)
Summary of Contents for 8155W
Page 5: ...5 Preparation Tools Needed 3 16 5 32 5 16 7 16 1 2 5 8 9 16 1 4 7 16...
Page 58: ...5 Pr paration Outils n cessaires 3 16 5 32 5 16 7 16 1 2 5 8 9 16 1 4 7 16...
Page 72: ...19 Installation Trolley Release Arm FOR T RAIL...
Page 114: ...5 Preparaci n Herramientas necesarias 3 16 5 32 5 16 7 16 1 2 5 8 9 16 1 4 7 16...
Page 128: ...19 Instalaci n Trolley Release Arm FOR T RAIL...