Chamberlain 1025 Owner'S Manual Download Page 6

GRANT ACCESS

0-9, A-Z

SCROLL

BLOCK USER

DELETE USER

ENTER

ADD USER

SETUP/EXIT

RELAY OUTPUT

N.O. contacts

SERIAL PORT

VOLT

SELECT

24

VAC

12/24

VOLTS

AC/DC

EXT.

GRANT

SWITCH

N.E.C. CLASS 2 

WIRING ONLY

Antenna

Display

Mounting

Holes

Power Supply

Inputs

Voltage Select

Jumpers

Serial Port

for Computer

or Printer

Output

Terminals

Grant

Access

Button

TM

Display Contrast
Adjustment

 

2

MODEL 1025LM

6

COMPONENT LAYOUT

Summary of Contents for 1025

Page 1: ... MUST be installed on the bottom of the door Failure to install a reversing edge under these circumstances may result in serious injury or death to persons trapped beneath the door WARNING GRANT ACCESS 0 9 A Z SCROLL BLOCK USER DELETE USER ENTER ADD USER DEVICE SETUP RELAY OUTPUT N O contacts SERIAL PORT VOLT SELECT ACRx 2 MODEL 1025LM KEEP TERMINALS COVERED HAZARDOU S VOLTAGES 24 VAC 12 24 VOLTS ...

Page 2: ...o 37 V AC DC at 150 mA or 12 VDC at 200 mA minimum Using an 85LM wall mount transformer Install the voltage select jumpers J4 J6 in the 24v position and plug the transformer jack into the receptacle to the right of the voltage jumper Wire the relay contacts to Push Button and Common as shown in the wiring diagram Using gate door operator power Install the voltage select jumpers J4 J6 in the positi...

Page 3: ... Z 0 9 Lift Master ACRx model G1000 16 CHARACTER LCD relay BLOCK USER DELETE USER GRANT ACCESS ENTER exit ADD USER SCROLL DEVICE SETUP 12 24v AC DC external GRANT sw 24v wallpack RELAY OUTPUT N O contacts SERIAL PORT V O L T A G E S E L E C T O R HAZARDOUSVOLTAGES PRESENT KEEP TERMINALS COVERED audio alert A Z 0 9 Lift Master ACRx model G1000 16 CHARACTER LCD 3 C Amplifier used without the cable l...

Page 4: ...y contacts will close for 1 3 seconds each time a valid user s transmitter code is received This is the factory default state of the ACRx 2 and the most commonly used On When Receiving The relay contacts will close when a valid transmitter code is received and remain closed until the user releases his transmitter button Toggle ON OFF The relay contacts will close when a valid transmitter code is r...

Page 5: ... 4 digit password before closing the contacts SERIAL PORT The ACRx 2 includes a computer connection which can be used to attach a computer or printer This is a standard RS 232 serial port although a special adapter cable is required to connect to the ACRx 2 When attached to a serial interface computer printer the ACRx 2 will print a log of all activities as they occur Line messages include self te...

Page 6: ... SERIAL PORT VOLT SELECT 24 VAC 12 24 VOLTS AC DC EXT GRANT SWITCH N E C CLASS 2 WIRING ONLY Antenna Display Mounting Holes Power Supply Inputs Voltage Select Jumpers Serial Port for Computer or Printer Output Terminals Grant Access Button TM Display Contrast Adjustment 2 MODEL1025LM 6 COMPONENT LAYOUT ...

Page 7: ...ace in car A single user cannot obtain access Green light on ACRx 2 flashes LCD message does not change Repeat the Add User routine A single user cannot obtain access Green light Replace transmitter battery or replace and reprogram on ACRx 2 does not flash transmitter When Grant Access button is pushed ACRx 2 relay clicks but door gate does not open Check door operator and wiring ACRx 2 prints inc...

Page 8: ... 1995 The Chamberlain Group Inc 01 12615B All Rights Reserved Printed in Mexico ...