RELAY OUTPUT

N.O. contacts

SERIAL PORT

12

SELECT

24

VAC

12/24

VOLTS

AC/DC

EXT.

GRANT

SWITCH

N.E.C. CLASS 2 

WIRING ONLY

Radio Power

Common

Push Button

Doorbell 

Button

Voltage select jumpers:

Place jumpers on bottom 2 pins for 24V operation

Place both jumpers on top 2 pins 12v operation

The ACRx 2 uses low voltage wiring only. Attach the
ACRx only to circuits or devices that are NEC Class 2
(less than 37VAC). Do not run wires to or from the
ACRx 2 in any conduit or box where there are AC
supply (120VAC) circuits. Failure to follow this
warning could result in electrical shock or fire and
damage to the ACRx 2.

WARNING

2

Mounting the Box

Choose a location for the ACRx 2 1025 control box which is:

• Protected from tampering
• As close to the approaching vehicles as possible for best

reception.

• Protected from moisture.

• Suitable for permanent attachment by mounting screws.

• Accessible to necessary wiring.

Hold the ACRx 2  control box in its intended mounting
location. Make sure the cover opens freely, with the display and
controls at a comfortable height and angle for viewing and use.
Use the holes in the ACRx 2 box for marking and drilling
attachment holes. 

Antenna Placement

For best range, placement of the antenna is crucial. Follow
these guidelines for best results.

•Make sure there is no interfering signal an the same channel as
the ACRx 2.  You can monitor channel activity with the
Liftmaster M-18 Test Set.  On-channel interference is not only
due to transmitters, but can also be caused by computing
devices, security systems, and other nearby electronic devices.
Power invertors and battery chargers are known sources of
interference.

Wiring requirements

P

ower can be provided with an 85LM wall mount transformer or

Radio Power from a gate operator (17 to 37 V AC/DC at 150
mA or 12 VDC at 200 mA minimum.)

Using an 85LM wall mount transformer: Install the voltage
select jumpers (J4 & J6) in the 24v position and plug the
transformer jack into the receptacle to the right of the voltage
jumper.  Wire the relay contacts to Push Button and Common as
shown in the wiring diagram 

Using gate/door operator power: Install the voltage select
jumpers (J4 & J6) in the position that matches the power
supplied by the operator.  Wire ACRx 2 to the operator as
shown in the wiring diagram.

• The ACRx 2 antenna system can be configured in several
ways.  Each installation is different, so there is no best antenna
system.  Try the different configurations of antenna placement
and amplifier until the best range is encountered.  Do this
BEFORE hard -mounting the antenna and permanently routing
the cable.

The typical antenna configurations are as follows on page 3:

• The antenna must not be next to, or enclosed in, metal.

• Place the antenna outside of any housing, box, or building,
even if the housing is not made of metal.  Non-metallic
structures can contain conduit, metallic-foil insulation, or be
painted with metallic paint.

• Place the antenna as high as possible, in sight of the expected
location of the transmitters. This is very important.

• Consider the direction from which the transmitters will be
used.  Place the antenna so that there are no structures or metal
obstructions between the transmitters and receiving antenna.•
Make certain that the amplifier, if used is oriented correctly.
The label indicates the end of the amp which must be connected
to the ACRx 2 or to the cable leading to the ACRx 2.  The amp
will not work properly if installed backwards.

• If longer coaxial cable is needed, do not splice cables together.
Instead, purchase a ready-made cable of the desired length from
a radio/tv store.  Use 75-ohm cable with CATV connectors
(also called type “F” connectors).

WIRING INSTRUCTIONS

WIRING DIAGRAM

ACRX & ANTENNA MOUNTING INSTRUCTIONS

Summary of Contents for 1025

Page 1: ... MUST be installed on the bottom of the door Failure to install a reversing edge under these circumstances may result in serious injury or death to persons trapped beneath the door WARNING GRANT ACCESS 0 9 A Z SCROLL BLOCK USER DELETE USER ENTER ADD USER DEVICE SETUP RELAY OUTPUT N O contacts SERIAL PORT VOLT SELECT ACRx 2 MODEL 1025LM KEEP TERMINALS COVERED HAZARDOU S VOLTAGES 24 VAC 12 24 VOLTS ...

Page 2: ...o 37 V AC DC at 150 mA or 12 VDC at 200 mA minimum Using an 85LM wall mount transformer Install the voltage select jumpers J4 J6 in the 24v position and plug the transformer jack into the receptacle to the right of the voltage jumper Wire the relay contacts to Push Button and Common as shown in the wiring diagram Using gate door operator power Install the voltage select jumpers J4 J6 in the positi...

Page 3: ... Z 0 9 Lift Master ACRx model G1000 16 CHARACTER LCD relay BLOCK USER DELETE USER GRANT ACCESS ENTER exit ADD USER SCROLL DEVICE SETUP 12 24v AC DC external GRANT sw 24v wallpack RELAY OUTPUT N O contacts SERIAL PORT V O L T A G E S E L E C T O R HAZARDOUSVOLTAGES PRESENT KEEP TERMINALS COVERED audio alert A Z 0 9 Lift Master ACRx model G1000 16 CHARACTER LCD 3 C Amplifier used without the cable l...

Page 4: ...y contacts will close for 1 3 seconds each time a valid user s transmitter code is received This is the factory default state of the ACRx 2 and the most commonly used On When Receiving The relay contacts will close when a valid transmitter code is received and remain closed until the user releases his transmitter button Toggle ON OFF The relay contacts will close when a valid transmitter code is r...

Page 5: ... 4 digit password before closing the contacts SERIAL PORT The ACRx 2 includes a computer connection which can be used to attach a computer or printer This is a standard RS 232 serial port although a special adapter cable is required to connect to the ACRx 2 When attached to a serial interface computer printer the ACRx 2 will print a log of all activities as they occur Line messages include self te...

Page 6: ... SERIAL PORT VOLT SELECT 24 VAC 12 24 VOLTS AC DC EXT GRANT SWITCH N E C CLASS 2 WIRING ONLY Antenna Display Mounting Holes Power Supply Inputs Voltage Select Jumpers Serial Port for Computer or Printer Output Terminals Grant Access Button TM Display Contrast Adjustment 2 MODEL1025LM 6 COMPONENT LAYOUT ...

Page 7: ...ace in car A single user cannot obtain access Green light on ACRx 2 flashes LCD message does not change Repeat the Add User routine A single user cannot obtain access Green light Replace transmitter battery or replace and reprogram on ACRx 2 does not flash transmitter When Grant Access button is pushed ACRx 2 relay clicks but door gate does not open Check door operator and wiring ACRx 2 prints inc...

Page 8: ... 1995 The Chamberlain Group Inc 01 12615B All Rights Reserved Printed in Mexico ...

Reviews: