Chalmit Protecta III 02L Installation, Operation And Maintenance Instructions Download Page 9

 

  

 
 

 

 

I-PR3C-03.doc   

 

Issue 03  

 

17/01/2022 

 

 

 

 
 
 
 

                                             IOM 

 

PROTECTA LED Ex ec

 

 

 

EU/UK-Declaration of conformity
UE-Déclaration de conformité 
EU-Konformitätserklärung 

 

 

Manufacturer 

Chalmit 

Address

388 Hillington Road, Glasgow. G52 4BL Scotland UK 

Product 

Protecta Ill LED Inotec Central Battery System

Notified Body 

CML B.V.  2776 

Type Examination Certificate 

CML 21ATEX3109X

 
Approved Body 

Eurofins CML   2503

Type Examination Certificate 

CML 21UKEX31271X

ATEX/UKEX Coding  

             II 3 GD 

ATEX/UKEX Classification 

Group II Category 3 GD

Equipment Coding 

Ex ec IIC T4 Gc, Ex tc IIIC T75°C Dc 

Ingress Protection 

IP66/67 

The technical basis, with respect to equivalence of

 

La base technique, en ce qui concerne l'équivalence de 
Die technische Grundlage hinsichtlich der Normen 
Protection Standards EN 60079-0, EN 60079-7, EN 60079-31
Area Classification EN 60079-10-1, EN 60079-10-2.

 

 

of compliance with the EHSRs is valid as there are no changes which materially affect the state of technological progress of the product.
en conformité avec les EESS est valide puisqu'il n'y a aucun changement qui affecte matériellement l'état de l'évolution technologique du 
produit. 
zur Erfüllung der GSGA ist gegeben, da keine Änderungen erfolgt sind, die einen Einfluss auf den technischen Stand des Produkts haben.

 

Terms of the directive:

 

Standard & Date Certified to

 

Standards Date Declared to

Prescription de la directive:

 

Standard & date certifiée à

Normes date Déclaré

Bestimmungen der Richtlinie:

 

Standard & Datum 
Zertifiziert nach

Standards Datum erklärt

 

2014/34/EU 

Sl 2016 No.1107 

Equipment and protective systems intended for use 
in potentially explosive atmospheres.

EN 60079-0: 2018

 

EN 60079-7: 2015 +A1:2018 

 

2014/34/UE 

Appareils et les systèmes de protection destinés à 
être utilisés en atmosphères potentiellement 
explosibles.

 

EN 60079-31: 2014 
 

 

2014/34/EU 

Geräte und Schutzsysteme zur bestimmungs- 
gemäßen Verwendung in explosionsfähigen 
Bereichen.

 

 

 

 

 

 

2014/30/EU 

Regulations 2016 

Electromagnetic compatibility

 

EN 55015 : 2019 

 

2014/30/UE 

Compatibilité électromagnétique

 

EN 61547 : 2009

 

2014/30/EU 

Elektromagnetische Verträglichkeit

EN 61000-3-2 : 2019

 

 

 

 

2014/35/EU 

Regulations 2016 

Low voltage equipment

 

EN 60598-1 : 2015 

 

2014/35/UE 

Équipements électriques à bas voltage

EN 60529 : 1992+A2:2013

 

2014/35/EU 

Niederspannungsgeräte / -systeme

 

 

 

 

2012/19/EU 

Regulations 2012

 

Waste of electrical and electronic equipment

 

 

 

2012/19/UE 

Déchets d'équipements électriques et électroniques

 

2012/19/EU 

Entsorgung der elektrischen und  elektronischen 
Geräte / Systeme

 

 

 

 

 

 

2011/65/EU 

Regulations 2012

 

RoHS II Directive

 

 

 

Summary of Contents for Protecta III 02L

Page 1: ...minaires for use with Inotec Central Battery System CBS ATEX IECEx and UKEX Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices...

Page 2: ...U by reason of the Type Examination EU Type Examination and meets the UK statutory requirements Sl 2016 No 1107 and compliance with the Essential Health and Safety Requirements M Poutney Technical Man...

Page 3: ...tially explosive atmosphere consideration should be given to verifying that the maximum surface temperature of the luminaire is below the ignition temperature of the hybrid mixture 3 1 3 Cleaning The...

Page 4: ...uct is certified for ATEX IECEx and UKEX and to comply with the certification for installation cable glands and sealing plugs must be ATEX IECEx or UKEX certified depending on site requirements Cable...

Page 5: ...ring between body and tray Replace in reverse order 3 8 4 Retro Fitting Lamps to LED s Before opening the front cover ensure that the luminaire is isolated from the mains supply Access for retro fitti...

Page 6: ...nts and the body parts may give off noxious fumes if incinerated Take care to render these fumes harmless or avoid inhalation Any local regulations concerning disposal must be complied with Any dispos...

Page 7: ...Watts Line Current Inrush Current Duration 02L JSVS 2 x 560mm 2296 400mA 18 0 08A 31A 41 s 04L JSVS 2 x 1120mm 3526 300mA 25 0 11A 27A 41 s 07L JSVS 2 x 1120mm 6596 600mA 54 0 24A 22A 42 s 02L JSVT 2...

Page 8: ...I PR3C 03 doc Issue 03 17 01 2022 8 IOM PROTECTA LED Ex ec...

Page 9: ...gegeben da keine nderungen erfolgt sind die einen Einfluss auf den technischen Stand des Produkts haben Terms of the directive Standard Date Certified to Standards Date Declared to Prescription de la...

Page 10: ...Produkts der Produkte zusammen mit dieser Erkl rung das Ger t die Ger te alle technischen und regulativen Anforderungen der oben aufgef hrten Direktiven erf llt Name and Date Mark Poutney 17 01 2022...

Reviews: