background image

-5-

-4-

GENERAL SAFETY INSTRUCTIONS

COMPONENTS

PARTS LIST

1. 

Safety 

valve 

 

   2. 

Filler 

cap

3. 

Steam 

outlet 

 

   4. 

Flexible 

steam 

hose

5. 

Steam 

plate 

 

   6. 

Element 

socket

7. 

Steam 

nozzle 

 

   8. 

Small 

brush 

3

9. 

Large 

brush 

 

   10.Rubber 

profile 

window 

cleaner

11.Handle 

 

   12.Mains 

power 

cable

13.Bonnet 

 

   14.Extension 

tube 

2

15.Joining Piece

17. Do not use the boiler near surfaces that may be damaged by the heat,
      ie.below and to the side.
18. Steam is produced at 100

o

C. Be careful, wear protective clothing and protect

      your hands with heat resistant gloves or mitts.
19. Always keep steam plate tilted away from face and body, beware of hot drips
      and regularly empty collected condensation from plate - especially when
      stripping ceilings and high areas.
20. Do not under any circumstances remove the hose or filler cap when in use.
21. Allow at least 5 minutes to cool down before you remove the filler cap.
22. Do not drag or try to move boiler by pulling either the hose or the mains lead.
23. Block boiler unit securely if using on stairs.
24. Take great care when working near electrical fittings, water must not enter
      these.
25. Never stand on unit or hose.
26. Check the condition of wall plaster before starting work, the steam could
      cause weak plaster to blow off the wall.
27. WARNING: DO NOT hold the steam plate over your head - beware very hot
      drips.
28. The boiler becomes hot in use. Move only by using the carrying handle.
29. Never point hose or steam plate at anyone.
30. Never block the safety valve.
31. Never use outside when raining.
32. Do not overfill.
33. Allow to cool completely before emptying boiler.
34. Do not stand on boiler or hose.
35. Use only standard tap water. Never add detergents or chemicals.
36. Extreme care must be taken if the unit is used in bathrooms. Always be
      aware of danger of electrocution from stored water in baths and sinks.
37. Never change tools when the unit is operating.
38. Always store upright.
39. It is recommended that a RCD ( residual current device) rated at 30mA is
      fitted into the mains supply socket for added protection against electric
      shock.

1

2 3

4

5

6

7

8

9

10

11

12

13

14

15

Summary of Contents for WS1064

Page 1: ...re or materials This Guarantee does not affect the statutory rights of the consumer If in the event of any problem occurring please Contact our Helpline at the number above for advice This product is not guaranteed for HIRE purpose Challenge Tools 1 ROEBUCK PLACE ROEBUCK ROAD CHESSINGTON SURREY KT9 1EU If faults cannot be remedied contact the Helplin on 020 83916767 Helpline hilka co uk Complete S...

Page 2: ...Inspect mains lead and extension leads periodically for damage if damaged have repair carried out by an authorised dealer Keep handles dry and clean 10 Disconnect Tools When not in use or attaching hose fitting always disconnect from mains supply 11 Use Outdoor Extension Leads Use an extension lead intended for the purpose 12 Do not use tool when tired 13 Check that tool is not damaged Before use ...

Page 3: ...or the mains lead 23 Block boiler unit securely if using on stairs 24 Take great care when working near electrical fittings water must not enter these 25 Never stand on unit or hose 26 Check the condition of wall plaster before starting work the steam could cause weak plaster to blow off the wall 27 WARNING DO NOT hold the steam plate over your head beware very hot drips 28 The boiler becomes hot ...

Page 4: ...re fully home then insert the hose through the assembled tubes Dia 6 3 Attach the end of the hose to the large brush then large brush then clip the end of the extension tube onto the large brush Part 9 Dia 7 Using the large brush The brush can be used by itself or with the bonnet as a carpet upholstery cleaner Some carpets have stain resistant treatments which may be affected by steam cleaning Try...

Page 5: ... with a safety cut out This may take a several minutes to reset 2 If the unit has been tipped over and the thermal safety cutout has been activated the thermal cutout will self reset after approximately 20 minutes 3 Possible debris in steamplate unplug allow unit to cool down and check 4 Hose may be kinked check and straighten 5 Check power supply and plug fuse 13amp 6 If you are using an extensio...

Page 6: ...e connected to the terminal which is marked with N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red The green yellow wire to the earth terminal marked E or If a 13 AMP BS 1363 plug is used a 13 AMP Fuse must be fitted or if any other type of plug is used a 13 AMP fuse must be fitted either in the plug or adaptor ...