Preparing the boiler for operation
48
GB
Confi guration of the temperature control by zones
Addressing the system interface
Expert control
1) Find menu
0
"Network"
then confi rm with the
OK
key. Select sub-
menu
03
"Interface system" then confi rm with the
OK
key.
2) Select sub-menu
030
"Zone number" then confi rm with the
OK
key and
assign a confi guration code to the system interface
Expert Control
:
- 0 no setting zone (Expert Control not assigned to any zone)
- 1 zone 1 setting (Expert Control assigned to heating zone 1)
- 2 zone 2 setting (Expert Control assigned to heating zone 2)
then confi rm with the
OK
key.
3) Carry out the same operation on each the system interface
Expert
Control
(if necessary).
4) Return to the main display by repeatedly pressing the
key
At this stage, the module is operational with the factory parameters.
Possible confi gurations (see below).
Zone 1
Zone 2
System interface
Expert Control
* The system interface
Expert Control
is connected to the
module
BUS
.
* Assign confi guration code "
1
" to parameter
030
on the sys-
tem interface
Expert Control
.
Zone Control
room sensor
* The
Zone Control
room sensor is connected to the module
BUS
.
* Refer to the
Zone Control
room sensor instructions to assign
it to Zone 1.
Easy Control
weekly room thermostat
* The
Easy Control
weekly room thermostat is connected to
the "
TA1
" terminal block on the module.
System interface
Expert Control
* The system interface
Expert Control
is connected to the
module
BUS
.
* Assign confi guration code "
2
" to parameter
030
on the sys-
tem interface
Expert Control
.
Zone Control
room sensor
* The
Zone Control
room sensor is connected to the module
BUS
.
* Refer to the
Zone Control
room sensor instructions to assign
it to Zone 2.
Easy Control
weekly room thermostat
* The
Easy Control
weekly room thermostat is connected to
the "
TA2
" terminal block on the module.