Preparing the boiler for operation
47
GB
Module programming
The are two options:
Scenario no. 1
: the boiler includes a
BUS
connection; confi gura-
tions are made from the boiler or from an the system interface
Expert
Control
(option).
Scenario no. 2
: the module is independent, and the zones are confi -
gured from the system interface
Expert Control
supplied as an option.
Initialisation
Before starting the procedure, check that all the circuits have water
and that the purge was carried out correctly.
Once all equipment is connected, the system recognises the equip-
ment and carries out automatic initialisation.
Confi guring the module
using the system interface
Expert Contro
1) Switch on the display by pressing the
OK
key. The screen is activa-
ted.
2) Press and hold the and
OK
keys on the system interface
Expert Control
simultaneously for 5 seconds.
3) Using the "encoder" button, display code
234
then confi rm with
the
OK
key.
4) Turn the button clockwise to access the
MENU
option then con-
fi rm with the
OK
key.
5) Look for menu
7
"Multizone Module" using the "enco-
der" button then confi rm with the
OK
key. Select sub-menu
72
"Multizone" then confi rm with the
OK
key. Select para-
meter
720
then confi rm with the
OK
key and select MCD
parameter
1
then confi rm with the
OK
key.
Confi guring the module from the boiler
1) Press the
menu/ok
key. When CODE
is displayed, press
menu/ok
; code
222
will appear.
2) Turn the "encoder" button to the
right then display code
234
and
confi rm with the
menu/ok
key.
3) MENU appears on the screen;
confi rm then select menu
7
and
confi rm with the
menu/ok
key.
4) Select sub-menu
72
and confi rm
with
the
menu/ok
key.
5) Select sub-menu
720
and confi rm
with
the
menu/ok
key.
6) Select parameter
1
and confi rm with
the
menu/ok
key (see Menu
720
in
the settings table).
9) Press the
esc
key repeatedly to return to the boiler display.
Air bleeding
The module's automatic air bleed function is only activated from the
boiler if there is a
BUS
connection (scenario no. 1).
The air bleed function is activated by pressing and holding the
esc
key on the boiler for 5 seconds or by activating parameter
7 0 1
.
With the bleed function activated, the module performs an ON/OFF
cycle of the Zone 1 circulating pump, the mixing valve and the gate
valve (option). This causes the air in the circuit to start circulating. You
can activate a new cycle if necessary.
Frost protection function
If the fl ow sensor records a temperature lower than 5°C, the frost
protection function is activated. If the frost protection function
is activated, the module opens the Zone 1 gate valve (option) and
starts the Zone 2 circulating pump. This allows frost protection to be
extended to zones 1 and 2.
Anti-jamming function
After every 24 hours of inactivity, an anti-jamming cycle is performed
on the circulating pump and the mixing valve.
OK
Encoder
OK
key
key
on/off
R
reset
mode
esc
menu/ok
comfort
sra
menu/ok
key
Encoder
esc
key