8.Parameters Explanation
Pr.01
406S Function selection
Setting range : 0 ~ 31
Factory setting : 8
Description : None
Pr.02 Response
time
Setting range : 0 ~ 99
Factory setting : 30
Description : As the setting value is low (high), voltage compensation speed
will be fast (slow) and response time quickly (slowly).
Pr.03
Accelerating and decelerating time adjust
Setting range : 1 ~ 99
Factory setting : 30
Description : The set is for time from 0 to target time. Small value means
response quickly; on the contrary, high value means slow
response time because long time processed.
Pr.04
Main speed “K” value
Setting range : 100 ~ 9999
Factory setting : 1000
Description : Steps:
1. Set the speed you want in Pr.04.
2. Adjust panel display to be 1000.
3. Start processing, then detect actual (linear) speed.
4. Adjust panel display to make actual (linear) speed equal to
Pr04.
5. Change Pr04 to be the value of panel display.