4.Explanations of Terminals
Power source Terminals 1 & 2 are AC power input.
Specification: AC 220V ± 3% 50/60 Hz
Terminal
3
is
F.G.
(earth
contact)
E1 and E2
Terminals 9 (+) and 10 (-) are power source of
Encoder inputs encoder, DC 12V±10%, 100mA (MAX)
Terminals 13 & 14 are feedback signal from the motor.
Start System
Terminals 15 & 16 are to start system. It is auto-control
model when short-circuited of starting terminal.
Parameters
Short-circuited Terminals 15 & 17 for modifying parameters
Setting content, detail operation methods, please refer to page 5.
Speed
Terminals 15 & 18 are speed acceleration contact A.
Adjustment Terminals 15 & 19 are speed deceleration contact A.
D/A Output Terminals 20 & 21 are D/A output 0~10V to
inverter or DC controller. Please use metal-shielded cable
and isolated to power lines.
※
Power source (+) and (-) must not be reversed.
EMAIL:[email protected]
Http://www.ch-sys.com
第
5
頁
Summary of Contents for SC-406S
Page 1: ...Speed Control SC 406S USER MANUAL 0...
Page 11: ...10...