![cGuard Litom User Manual Download Page 11](http://html1.mh-extra.com/html/cguard/litom/litom_user-manual_2585479011.webp)
10
Table 2. сGuard Litom channel list
Channel
Purpose
Values
Notes
CSQ1
GSM signal level
0..100%
NSQ1
Captured satellites quantity
0..24
NSQ2
Satellites data validity
0 or 1
1 – valid, 0 - invalid
AIN1, AIN2
Analog channels
0..30 V
DIN1, DIN2
Discrete channels
0 or 1
See
section 8.3
PWR1
Mains voltage
0..40 V
REL1
Relay control
0 or 1
1 – on, 0 - off
FRQ1, FRQ2
Frequency channels
0..2000 Hz
CNT1, CNT2
Pulse counter
0..4294967295
LLS1..LLS12
Digital sensors data (RS-485)
See
section 8.8
WIR1..WIR3
1Wire sensor temperature
See
section 8.9
IBT1
iButton ID
See
section 8.9
Table 3. Correspondence between logical channels and physical inputs of tracker
Inputs
Channels
AIN1
AIN1 – value of voltage on analog input
DIN1 – result of program comparator, comparing the analog input signal and
assigned threshold
AIN2
AIN2 - value of voltage on analog input
DIN2 - result of program comparator, comparing the analog input signal and
assigned threshold
FRQ1 (DIN1)
5
FRQ1 – frequency measuring
CNT1 – pulse counter
FRQ2 (DIN2)
5
FRQ2 – frequency measuring
CNT2 – pulse counter
RS-485
LLS1-LLS12
1Wire
WIR1..WIR3
IBT1 - for iButton
DOUT
REL1
7.2 Remote configuration
There are two data channels for remote configuration:
SMS
GPRS
The remote configuration guide and the list of available commands can be downloaded from our
website
.
GPRS configuration allows customizing device parameters and uploading device firmware.
SMS-commands can change device parameters and make requests for device status and location.
5
DIN marking was indicated on trackers cGuard Litom, manufactured earlier than September 2017.