- 15 -
Reason
1.the coil
sensor
terminals are
not securely
plugged in.
2.The coil
sensor fault .
3.If not above
question, It
maybe is
display panel
PCB fault.
1.The humidity
sensor
terminals are
not securely
plugged in.
2.The humidity
sensor fault .
3.If not above
question, It
maybe is
display panel
PCB fault.
Water is not
draining
from the pump
reservoir or
there is a lack
of power to the
water pump.
Remedy 1.Check to
ensure the coil
sensor
terminal is
securely
plugged in.
2.Replace the
coil sensor .
3.Replace
display panel
PCB
1. Check to
ensure the
humidity
sensor terminal
securely
plugged in.
2.Replace the
humidity
sensor .
3.Replace
display panel
PCB
1. Make sure
maximum lift is
not exceeded.
End of hose
should be no
higher than 10
feet above the
unit.
2. Check pump
for
debris or
blockage.
Dehumidifying Capacity
(30°C RH80%):
80L/day
(170 pins/day)
Dehumidifying Capacity
(26.7°C RH60%):
48L/day
(100 pins/day)
Rating Power Input / Current
(30°C RH80%):
1450W/6.4A
Rating Power Input / Current
(26.7°C RH60%):
1150W/5.1A