Installation & Maintenance

AXP

IN-LINE DUCT FANS

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Summary of Contents for AXP100

Page 1: ...Installation Maintenance AXP IN LINE DUCT FANS READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ...

Page 2: ...walls or ceilings take care not to damage electrical wires and other hidden utilities 6 When used to exhaust moist humid air fans must always be vented to the outdoors 7 This unit may have sharp edges Use caution to avoid injury when installing and cleaning 8 The fan is intended to be hard wired to a properly rated electrical circuit and must be properly grounded Do not use an extension cord 1 For...

Page 3: ...r 12 300mm diameter duct AXP C fans are equipped with a pre wired 120V power cord MODELS AXP MODELS AXP C The wiring diagram for AXP models is shown in Figure 8 and for AXP C models in Figure 9 Fans are designed for continuous operation Protection rating from access to dangerous parts and water penetration is IPX4 Fans can be operated at ambient temperatures between 32 F and 122 F 3 ...

Page 4: ... mounted in ventilation shafts either vertically or horizontally Figure 1 An air duct at least 40 inches 1 meter long should be connected to the inlet The outlet should always be connected to an air duct TYPICAL FAN INSTALLATION 4 ...

Page 5: ... any installation work Working on or near energized equipment could result in death or serious injury Fan installation is shown in Figures 2 7 The airflow direction should match that indicated on the fan housing Exhausted air must not contain any dust or other solid impurities sticky substances or fibrous materials 5 WARNING ...

Page 6: ...RMINAL BLOCK BLACK GROUND WHITE YELLOW BLACK BLUE FROM FUSE PANEL AXP FAN MOTOR BROWN 120 VOLT SUPPLY AXP C FAN STANDARD WALL SOCKET EARTH GROUND 120V AC 60Hz HOUSE POWER HOUSE JUNCTION BOX GREEN GROUND SCREW S1 AUTOMATIC SWITCH Figure 9 Figure 8 6 ...

Page 7: ...enance Figure 10 17 includes periodic cleaning of the fan surfaces from dirt and dust The impeller blades require thorough cleaning every 6 months Remove the self tapping screws Figures 12 and disconnect the grill from the casing Wipe the fan blades with a soft cloth soaked in a mild detergent avoiding dripping on the electric motor RECOMMENDED MAINTENANCE 7 WARNING ...

Page 8: ...0 C AXP200 C AXP250 C AXP300 C Manufactured on date Date of sale Sold by name of trading enterprise stamp of store Company name Electrician name Date Signature Due to constant product improvements some models may differ slightly from those portrayed in this manual AXP I M 1705 Buffalo New York Mississauga Ontario Dayton Ohio www continentalfan com 1 800 779 4021 ...