background image

G/01141C

 

Edition 1

 

27/04/2012

 

MD-4931CFA Handbook 

 

__________________________________________________________________________________________________ 

 

 

 

Operator Handbook for CFA Door Phone     G/01141C     Issue 1    Page 

 

1.2 DESCRIPTION

 

 

The 

CFA Door Phone

 

is consists of two main stainless steel / zincalume components: 

 

1.

 

The Front Door Plate 

 
This is a vandal resistant stainless steel plate (2 mm thick). It contains the weather resistant 
push button, microphone and speaker. 

 

2.

 

The Inside Hide-away Unit 

 

This is the control unit containing all the electronics, programmed data, auto-answer setting, and 
dialer. There are connectors for the front door plate, the telephone line, switched transistor 

output for a door/gate latch and optional power for when line power is insufficient. Optional 
sockets are available for another switched relay output, an external alarm input, and an RS232C 

serial port. 
 
The front door plate and the inside hide-away unit are simply connected to each other using the 

eight-wire cable provided (longer cables up to 30 meters to order). The inside hide-away unit is 
connected to any working telephone socket (pins 2 & 6 on a 610 socket or centre pins 3 & 4 on 

an RJ12 jack). RJ style plugs are provided. 
 

The MD-4931CFA is telephone line powered so the unit continues to operate in the event of 
mains power failure. 

 

FEATURES

 

 

 

Hands-free Front Door Telephone 

 

Security appliance 

 

Telephone dialer 

 

Push button activated 

 

Intercom to your mobile phone, PABX extension, or any other telephone 

 

Brushed stainless steel finish (brass plating and horizontal mounting optional) 

 

Back light on door plate (if plug pack is connected) 

 

Call Progress tones 

 

Speaker volume control 

 

Programmable PIN access 

 

Automatic disconnect 

 

Automatic push button redial (if the line is jammed up or busy, just press the button and 
you’ll be re-connected!!!) 

 

Compatible with all analogue telephone lines or extensions 

 

Programmable telephone number 

 

Door Opener - relay output to operate electric door strike/latch to open doors or gates etc. 

 

Alarm input to automatically dial a number in the event of an alarm (optional) 

 

Easy D.I.Y. installation 

 

Two Year warranty 

 

ACMA Supplier’s code N468 

 

Summary of Contents for MD-4931CFA

Page 1: ...01141C Issue 1 27 04 2012 CAT 5 SPLIT SYSTEM Design Two Thousand Pty Ltd ABN 45 005 014 639 9 11 Rose Street Upper Ferntree Gully Melbourne Victoria 3156 Australia Telephone 613 9758 5933 Facsimile 613 9758 5560 Email gen design2000 com au Web Site www design2000 com au All Rights Reserved Copyright Design 2000 Pty Ltd 2012 DOOR PHONE MD 4931CFA ...

Page 2: ...Operator Handbook for CFA Door Phone G 01141C Issue 1 ...

Page 3: ... Control Document ID G 01141C Document Name CFA Door Phone MD 4931CFA Handbook Security Commercial In Confidence Circulation Design 2000 Pty Ltd CFA Prepared By P Zeug Reviewed By R Kells Approved By Version Control Edition Date Notes 5 27 04 2012 CFA version based on MD 4900VP Copyright 2012 PRINTED IN AUSTRALIA _____________________________________________________________________________________...

Page 4: ... 2 2 Installation 3 2 1 Installation Block Diagram 3 2 2 Hide away Unit Mounting details 4 2 3 Connections 5 2 4 Wiring Diagram For Door Latch Output Mode 6 2 5 Push Button Light 6 3 User Instructions 7 3 1 To store the telephone number to be dialed 7 3 2 Call from the Door Phone 7 3 3 Call to the Door Phone 7 3 4 Door Opener 7 3 5 Speaker Volume 8 3 6 Force Disconnect 8 3 7 Silence Disconnect 8 3...

Page 5: ...__________________ Operator Handbook for CFA Door Phone G 01141C Issue 1 DESIGNED MANUFACTURED BY DESIGN TWO THOUSAND PTY LTD www design2000 com au gen design2000 com au N468 AUSTRALIAN OFFICE Design 2000 Pty Ltd 9 11 Rose Street Upper Ferntree Gully Melbourne Victoria 3156 Australia Sales Service Contact 03 9758 5933 03 9758 5560 ...

Page 6: ...ation As standard the CFA Door Phone has a relay output to control an electric door strike latch etc Optionally the CFA Door Phone can be ordered with alarm inputs to report alarm events and with more outputs to activate CCD cameras so that images can be captured on your personal computer Things that make this unit unique are its strength slim style performance and compatibility with any phone sys...

Page 7: ...sing the eight wire cable provided longer cables up to 30 meters to order The inside hide away unit is connected to any working telephone socket pins 2 6 on a 610 socket or centre pins 3 4 on an RJ12 jack RJ style plugs are provided The MD 4931CFA is telephone line powered so the unit continues to operate in the event of mains power failure FEATURES Hands free Front Door Telephone Security applian...

Page 8: ... Handbook __________________________________________________________________________________________________ Operator Handbook for CFA Door Phone G 01141C Issue 1 Page 3 2 INSTALLATION 2 1 INSTALLATION BLOCK DIAGRAM CFA DOOR PHONE MD 4931CFA ...

Page 9: ...WAY UNIT DIMENSIONS NOTE SCREW HEIGHT FROM MOUNTING SURFACE MUST NOT EXCEED 8mm 5 16 215 mm 110 mm 20mm 1 Disconnect all wiring from Hide away unit 2 3 4 5 Drill holes for mounting screw as shown in diagram Fit mounting screw to mounting surface and check that screw does not protrude more than 7mm from surface Locate Hide away unit onto mounting screw Connect wiring to Hide away unit HIDE AWAY UNI...

Page 10: ...he front door plate may be up to about thirty meters 0 4 mm diameter copper however noise may be introduced if the cable is unshielded and runs past sources of electrical interference We therefore strongly recommend that you use the cable supplied wherever possible or run a special cable with a shielded conductor for the microphone ie shield connected to MICROPHONE and the conductor connected to M...

Page 11: ...ed on an outgoing call This mode can be used to operate security cameras etc 1 Dial up the Door Phone set for auto answer from an independent telephone 2 Wait for it to answer with a double pip tone 3 Press enter your PIN normally none then press 601 4 Press 0 for both switched outputs to be activated only by DTMF 5 OR Press 1 for both switched outputs to be activated when button is pressed and an...

Page 12: ...3 2 How to make a call from the CFA Door Phone 1 Simply press the CALL button for about half a second or more 2 Listen for the dialing sound followed by ringing tone 3 Talk as required Note Pressing the push button during a call will re establish the call This is a fabulous feature designed to overcome the possibility of the system ever locking up the line 3 3 How to call the CFA Door Phone 1 Set ...

Page 13: ...3 Wait for it to answer with a double pip tone 4 Press 5 Enter your PIN normally none 6 Press 8 7 Enter the maximum number of seconds of silence detection on the line side for a door phone call to be automatically disconnected 0 no silence disconnect or 1 255 seconds Eg if you enter 30 seconds any call with a silence period on the line side of thirty seconds or more will be automatically disconnec...

Page 14: ...new call is automatically established 30 seconds of silence on the line side is detected Total call time limit has elapsed 3 11 Dial Long Tone Disconnect 3 seconds default Some telephone systems provide dial tone or long tones as the disconnect signal The MD 4931CFA may be programmed to disconnect after 1 second to 255 seconds of continuous tone two seconds minimum is recommended Summary PIN 603 t...

Page 15: ...elephone switches and VoIP analogue terminal adaptors can provide either North American busy tone or Australian busy tone All MD 4900 Series Door Phones can be set to detect either US or AUS default busy tones for automatic disconnect Instructions Remove the MD 4900 hideaway unit cover Locate LK2 the three pin US_AUS jumper link circled below in red Position the shunt in either the US or AUS posit...

Page 16: ...m during dialing and conversation Operating Temperature Range 10 50 C Storage Temperature Range 20 80 C ambient Humidity Storage and Operating To 98 non condensing Mean Time Between Failure 20 years Hands free Speakerphone Motorola MC33218AP semi duplex Output level 13 5 0 dBm adjustable Frequency range 300 Hz 3 4 kHz Line Interface Two wire analogue ring in loop out Programming method DTMF Push B...

Page 17: ...__________________________________ Operator Handbook for CFA Door Phone G 01141C Issue 1 Page 12 CFA DOOR PHONE MD 4931CFA HANDS FREE DOOR TELEPHONE Communication for Emergency Services MADE IN AUSTRALIA BY Est 1968 TELEPHONE 03 9758 5933 FAX 03 9758 5560 E MAIL gen design2000 com au WEB SITE www design2000 com au ...

Page 18: ... hide away unit 1 Four meter interconnecting cable Cable b w door plate and hide away unit 1 RJ12 to RJ12 telephone lead Connection to phone line 1 BL 4 screw terminal dc door strike 1 BL 3 screw terminal voltage free dry relay contacts 4 6g x 25 mm s steel Torx head no T10 screws Door Plate fasteners 5 Wall plug drill size 3 16 5 mm Masonry applications 1 6g x 25 mm cross recess pan head screw Wa...

Reviews: