Ceyear 87230 Series Quick Start Manual Download Page 4

 

 

Foreword 

Thank  you  for  choosing  and 
using  the  87230  series  CW 
power  sensor  researched  and 
produced  by  China  Electronics 
Technology  Instruments  Co., 
Ltd!  Our  product  is  high-end, 
precise  and  sophisticated,  and 
embraces 

high 

cost 

performance 

among 

the 

competitors of the same class. 

We are devoted to providing for 
you  high-quality  products  and 
first-class  after-sales  service 
with  your  most  concerns  and 
demands 

in 

mind. 

Our 

consistent  aim  is  providing 
excellent  quality  and  good 
service,  and  this is  our  sincere 
commitment for all users. 

 

Manual No.

 

AV2.984.1215SK 

 

Version 

A.1      2018.03   

China  Electronics  Technology 
Instruments Co., Ltd. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual Authorization

 

This manual may be subject to 
change  without  notice.  CETI 
reserves  all  the  rights  to  the 
final  explanation  for  all  the 
information  and  terminologies 
referred to in this manual. 

This  manual  is  the  property  of 
CETI. 

Without 

CETI's 

permission,  any  organizations 
or individuals shall neither alter 
nor 

duplicate/transmit 

this 

manual  for  profits;  otherwise, 
CETI  reserves  the  right  to 
pursue any liabilities therefrom. 

Product Warranty

 

The  warranty  period  of  this 
product  is  18  months  from  the 
date  of  delivery.  Instrument 
manufacturer  will  repair  or 
replace  the  damaged  parts 
according 

to 

the 

actual 

situation in the warranty period. 
The 

specific 

maintenance 

matters  should  be  subject  to 
the contract. 

Product Quality Certification 

This product is certified to fulfill 
the  standards  indicated  in  this 
manual from the day of delivery. 
Calibration 

measurements 

have been carried out based on 
national  standards.  Related 
information  is  available  to  the 
user for reference. 

Quality/environment 
management 

The  quality  and  environmental 
management  systems  have 
always 

been 

implemented 

during 

development, 

manufacturing  and  test  of  this 
product. 

China 

Electronics 

Technology  Instruments  Co., 
Ltd.  is  properly  qualified  and 
certified  by  ISO  9001  and  ISO 
14001  management  system 
standards. 

 

 

 

 

Safety Precautions 

 

 

"Caution" indicates a danger. It 
reminds the user to be cautious 
of  a  certain  operation  process, 
operation method or the similar. 
Failure  to  follow  the  rules  or 
operate  correctly  may  result  in 
the minor or moderate personal 
injury  and  equipment  damage. 
The  conditions  indicated  by 
CAUTION  should  be  fully 
understood and met before the 
next operation. 

 

 

 

CAUTION 

indicates 

an 

important  information  rather 
than  danger.  It  reminds  the 
user to be cautious of a certain 
operation  process,  operation 
method or the similar. Failure to 
follow  the  rules  or  operate 
correctly 

may 

cause 

the 

damage  to  the  instrument  or 
loss  of  important  data.  The 
conditions 

indicated 

by 

CAUTION  should  be  fully 
understood and met before the 
next operation. 

 

 

 

ATTENTION

 

CAUTION

 

!

           

Summary of Contents for 87230 Series

Page 1: ...87230 Series USB CW Power Sensor Quick Start Guide...

Page 2: ......

Page 3: ...50MHz 26 5GHz 87233 50MHz 40GHz Options English options English menu and English interface for Export models Version A 1 March 2018 China Electronics Technology Instruments Co Ltd Address No 98 Xiang...

Page 4: ...ctual situation in the warranty period The specific maintenance matters should be subject to the contract Product Quality Certification This product is certified to fulfill the standards indicated in...

Page 5: ......

Page 6: ...fore use 3 2 1 Preparation before Operation 3 2 2 Routine Maintenance 10 3 Typical Applications 12 3 1 Selection of Power Sensor 12 3 2 Virtual Power Measurement Panel 12 3 3 Zeroing and Calibration B...

Page 7: ......

Page 8: ...of all functions of the instrument including sensor selection virtual panel introduction zero and calibration before measurement and continuous wave power measurement which is intended to make users u...

Page 9: ...al describes the basics of remote control programming basics of SCPI SCPIs examples of programming and I O driver library for the purpose of guiding the user to master the SCPIs and methods of the ins...

Page 10: ...der warranty we will no longer provide the unpaid repairs Please carefully read relevant content of 2 2 Safe Use Guideline of the User s Manual and the following precautions for safe operation In addi...

Page 11: ...the following steps Step 2 Unpack the instrument and check for any damage to the main unit and attached items Step 3 Verify the items in the packaging box carefully by cross checking with Table 2 1 S...

Page 12: ...equipment Generally we will use two anti static measures including combination of conductive table mat and wrist combination as well as combination of conductive floor mat and ankle strap If these tw...

Page 13: ...rogramming software including Microsoft Visual Basics C and LabVIEW 2 USB cable selection The 87230 series USB CW power sensor is equipped with special USB cable which can be screwed and fixed on the...

Page 14: ...measurement instrument USB host interface and the power sensor green indicator lamp will light up later Step 2 The Equipment Manager of the host can find the new USB Test and Measurement Devices Fig 2...

Page 15: ...fore measurement and connection to ensure that they are clean and undamaged It is necessary to wear an anti static wrist strap during connection The correct connection methods and procedures are as fo...

Page 16: ...efore applying a force Gently grasp the end of the torque wrench handle and apply a force in the direction perpendicular to the handle until the breakout torque of the wrench is reached Fig 2 6 Use of...

Page 17: ...or used an adapter must be adopted for measurement connection In addition even if the measurement port of the analyzer is the same as the type of connector for the port of tested part it is also a goo...

Page 18: ...and a microwave power signal input port If the connector is damaged or there is dust inside the RF wave band test results will be affected therefore please observe the following methods for maintenan...

Page 19: ...s wave power measurement As the performance specifications are different by model the user can select the suitable sensor according to the characteristics and measurement requirements of signals to be...

Page 20: ...evice to be connected in the pop up Instrument Connection window in the system and click Connection button As shown in Fig 3 3 the measurement process is normal Step 2 The user can check the type seri...

Page 21: ...nd thus calibration is not recommended to the users 3 3 1 Zeroing Zeroing refers to measurement and storage of noise of the whole measurement channel In the process of measurement the zeroed value sha...

Page 22: ...During measurement of low level signal automatic zero shall be carried out before measurement so as to ensure the measurement accuracy Set the step detection to Off status when the measurement of low...

Page 23: ...er sensors into the computer or build a multi channel power test system with USB HUB as shown in Fig 3 4 Fig 3 4 Multi channel Power Test with USB HUB The specific operation steps are as follows Step...

Page 24: ...the currently selected measurement window with yellow border and then select the Equipment drop down menu under the System label to assign the window to other equipment Step 4 Click one measurement w...

Page 25: ...iagnosis and Guides This part provides general guidance on how to carry out simple judgment and handling when the 87230 series USB CW power sensor has any fault If necessary please feed back the probl...

Page 26: ...udged clearly Check whether the mechanical connection of the USB cable is correct and whether the electric characteristics are compatible When the problems appears after some settings are made check t...

Page 27: ...the USB power sensor along with the apparatus in the packaging box 2 Pack the USB CW power sensor with the original packaging material to reduce possible damage 3 Put the linings at four corners of t...

Reviews: