background image

Instruction Handbook                          PFP-13hpHND-EM-HP80  

- 6 -

 

 C.E.T. Fire Pumps Mfg. This handbook is subject to change without notice, 

Contact your local C.E.T. dealer or C.E.T. direct to ensure you have the latest version.

 

o

 

NEVER run the pump for more than one minute without water.  

o

 

NEVER run the engine without the proper amount of oil in the engine. 

o

 

NEVER alter the engine and/or the pump even partially.  

 

 

Signs and Symbols 

 

 This warning symbol means that not following the attached note will put at 

risk  the  security  of  the  personnel  operating  near  the  pump.  The  words 

“danger”, “warning” and “caution” are used 

for levels of risk. 

 

This symbol means that it is mandatory to read and understand this handbook 

as well as the operation manual from the engine manufacturer, BEFORE you 

start the engine.  

 

This symbol represents the risk of injury from high temperature surfaces. 

 

This symbol represents the risk of intoxication from dangerous gases, such 

as carbon monoxide. 

 

This symbol represents the risk of injury caused by moving parts.  

 

This symbol represents the hazards of handling dangerous material such as 

gasoline or diesel. 

 

CAUTION 

 

Summary of Contents for PFP-13hpHND-EM-HP80

Page 1: ...C E T direct to ensure you have the latest version Instruction Handbook Version 1 0 Model PFP 13hpHND EM HP80 Your version of the pump the engine and their accessories may vary from the one seen on th...

Page 2: ...or C E T direct to ensure you have the latest version Table of contents 1 FOREWORD 3 2 SAFETY INSTRUCTIONS 4 3 DESCRIPTION 7 4 GENERAL INSTRUCTIONS 10 5 TRANSPORT AND STORAGE 11 6 PERFORMANCE 12 7 STA...

Page 3: ...ury of experience in building fire fighting equipment If you follow the directives given in this handbook your pump will be a useful ally for many years to come For your own safety and those around yo...

Page 4: ...ffler o NEVER run the engine without a muffler or proper exhaust system o NEVER operate the engine if the fuel tank cap is removed do not fill the tank while the engine is running If fuel is spilled m...

Page 5: ...y hot water scald and burn hazards NEVER let the pump run for more than one minute with discharge valve s completely closed When the pump is running make sure to always leave the discharge valve sligh...

Page 6: ...he attached note will put at risk the security of the personnel operating near the pump The words danger warning and caution are used for levels of risk This symbol means that it is mandatory to read...

Page 7: ...n 3 Description This portable pump is directly driven by the very high quality Honda gasoline 13 hp engine It is equipped with an electric starter and also has a backup recoil starter It has an integr...

Page 8: ...h resistance aluminum alloy body It also has an axial mechanical seal The pump can operate to a maximum pressure of 115 PSI 7 9bar It has been designed to work at a temperature between 5 F 15 C and 10...

Page 9: ...ventilated area Recommended individual protective equipments not included Firefighting grade protective gloves conforms to EN659 or equivalent Protective glasses Hearing protection Intended use for ap...

Page 10: ...er at the end of the suction hose If you are not sure of the quality of the pumped water use a floating strainer to prevent drawing the sand or stone from bottom source The Honda GX390 engine is certi...

Page 11: ...cially if the engine has oil in it Storage Warning It is important to take into account the dangerous materials and components such as diesel oil and the battery Store away from heat source flames and...

Page 12: ...al conditions geostatic height of 4 10 1 5m temperature de 59 F 15 C water clear of sand and debris atmospheric pressure 3280 1000m from sea level None conformance to the instructions given in this ha...

Page 13: ...o ensure you have the latest version 7 Starting procedure 7 1 Place the pump on a flat and stable surface with an angle less than 15 Place your pump as close as possible to the water source WARNING NE...

Page 14: ...nding people before you start the pump It is important that you evaluate the trajectory of the hose to prevent incidents NOTE If you are pumping from a hydrant replace step 7 5 by open the valve or an...

Page 15: ...the engine with the throttle control to its maximum speed 7 9 When water comes out of the manifold top and out of the discharge hose it should take approximately 15 to 30 seconds when priming from 10...

Page 16: ...nge without notice Contact your local C E T dealer or C E T direct to ensure you have the latest version WARNING NEVER run the pump at high speed with the discharge valve or nozzle closed more than on...

Page 17: ...ve water inside the casing of the pump and valves The water could freeze and damage them CAUTION After each use it is important to flush the inside of your pump with fresh water This will help prevent...

Page 18: ...commend you do a functional test Functional test Connect suction hose of 3 diameter and a length of 10 Make sure to completely submerge the end of the suction hose at least 12 Connect a discharge hose...

Page 19: ...ct Dispose properly of the used oil and filters according to the local environmental regulations WARNING Never run the pump if the inlet strainer is not on or is damaged Maintenance Interval Daily Fir...

Page 20: ...ir tight Make sure to have well understood and applied the priming protocol of the pump Check for any possible air leakage in the suction hose Check the mechanical seal for leakage Faulty engine Refer...

Page 21: ...deposits or dust is obstructing the priming system Carefully dismantle the priming system clean it up or replace the components if necessary The engine runs fine but the pump output is low The restric...

Page 22: ...IRE PUMPS MFG incurs no liability under this warranty or otherwise for equipment which has been abused altered or improperly maintained or for equipment which has been returned for inspection or repai...

Page 23: ...E T direct to ensure you have the latest version 13 Contact Us For repair or questions about warranties please contact your local C E T fire pumps dealer E mail service fire pump com Tel 1 450 568 27...