16
Version 1.0
•
DME 2 Option:
1)
Rotate the large knob to the left until in the GROUP field.
2)
Rotate the small knob to drop the menu down, and highlight ‘Options’ in the
GROUP field.
3)
Press the Enter key.
4)
Rotate the small knob to drop the menu down, and highlight ‘DME 2 Option’ in
the ITEM field.
5)
Press the Enter key.
6)
All boxes should be checked. These are:
Airframe
GSD41 2
7)
Select the LOAD softkey at the bottom of the display.
8)
Monitor the configuration load to verify the green PASS message next to each
item.
9)
Press the Enter key when all the loading is complete to acknowledge the upload is
complete window.
Note: Each option using an unlock card is assuming this is the first you are loading. If you have
already loaded an option with an unlock card, then steps 1 & 2 are already complete
•
Synthetic Vision (SVS):
1)
Pull the L PFD circuit breaker (if not already done).
2)
Remove the 010-01121-10 software loader card from the upper slot of PFD 1 if
installed.
3)
Insert the 010-00330-55 SVS Unlock card into the upper slot of PFD 1.
4)
Press and hold the #12 softkey on the PFD 1 push the L PFD circuit breaker in.
5)
Let go when you see initializing.
6)
PFD 1 should be on the system upload page.
7)
Activate the cursor by pushing down on the FMS knob.
8)
Rotate the small knob to drop the menu down, and highlight ‘Configuration Files’
in the GROUP field.
9)
Press the Enter key.
10)
Rotate the small knob to drop the menu down, and highlight ‘Enable SVS Dual
PFD’ in the ITEM field.
11)
Press the Enter key.
12)
All boxes should be checked.