background image

9.2 Decoupling

Coupling consists of connections between two devices:

l

From the communication module to the lock, and

l

from the lock to the communication module.

For this reason, decoupling has to occur for both devices:

For the lock

By means of the configuration menu

For details, please refer to the

CESeasy manual for motor cylinders

.

Or

For details, please refer to the

CESeasy door controller manual

.

For the

communication

module

By resetting the communication module (see

"Reset of the communication module"

on the facing page)

9.3 Coupling to a new lock

You can couple the communication module to a second lock without having to end the coupling

connection to the communication module beforehand (= reset). The old connection information is

automatically overwritten.

Do not forget to delete the coupling in the first lock. Otherwise, the lock will permanently

and unsuccessfully try to connect to the communication module.

Page 26 of 37

CESeasy communication module

9   How to couple a lock

Summary of Contents for CESeasy 347102V

Page 1: ...CESeasy Communication module Assembly and Operating Manual English Version VB BRO2280 2...

Page 2: ...with batteries 7 4 CESeasy communication module 9 4 1 About communication modules 9 4 2 Scope of application 9 5 Scope of delivery 10 6 Assembly 11 7 Connections 14 7 1 How to connect the power suppl...

Page 3: ...are 27 10 2 Reset of the communication module 27 11 Operation 29 11 1 Privacy mode 29 11 2 Night locking mode only motor cylinders 29 12 Technical data 31 12 1 Equipment features 31 12 2 Dimensions 32...

Page 4: ...this manual is shown on the cover page You can get the latest version free of charge from www ces eu 1 1 Design characteristics Refers to other documents Marks additional information and tips Marks w...

Page 5: ...ed by deficient assembly l Damage caused by deficient maintenance l Damage caused by false operation l Damage caused by overvoltage l Damage caused by fire water or smoke All technical data and featur...

Page 6: ...nstitute function related hazards for the user or third parties and may impair the handle set and other material assets Please observe all warnings and notices in this manual while assembling configur...

Page 7: ...mosphere chlorine ammonia lime water l Do not use the device in areas with high dust formation l Do not use the device near heat sources Please observe the maximum permissible temperatures and the inf...

Page 8: ...ately from the device Clean the contacts before inserting new batteries There is danger of injury from battery acid l Remove the empty batteries from the device l Please take note of the information o...

Page 9: ...e additional outputs which reflect the lock status The communication module and the lock communicate wirelessly 4 2 Scope of application Due to the available inputs and outputs and the functions which...

Page 10: ...5 Scope of delivery 1 1 Communication module 2 2 Batteries 3 1 Power supply unit Page 10 of 37 CESeasy communication module 5 Scope of delivery...

Page 11: ...e proximity These factors can absorb or reflect the radio signal which is why it is not possible to make a general statement about the maximum distance In most cases a distance of up to 10m within a b...

Page 12: ...the communication module with at least two 4mm countersunk head screws to a level surface The length of the screws depends on the surface Depending on the surface you may have to use suitable dowels...

Page 13: ...ing in the battery compartment which indicates the correct polarity 6 Link the communication module to your lock see How to couple a lock on page 24 7 Check if the communication module is working corr...

Page 14: ...l marked 12VCD and GND Make sure to connect the power supply unit correctly to the positive and negative terminal Run the connecting cables through the recess of the case towards the outside Before co...

Page 15: ...ched simultaneously they react as follows If both inputs are activated the order Open is sent to the coupled lock If both inputs are deactivated the order Close is sent to the coupled lock IN2 Close T...

Page 16: ...1 afterwards still remains activated and e g a Close order is sent by the CESeasy app the lock will carry out the Close order but will not react to input 1 anymore although it is still active Only if...

Page 17: ...nnected e g a switch or a relay As soon as the contact closes INx is con sidered to be active Example 2 Open collector output A Open collector output B Device with an output C Communication module A d...

Page 18: ...d lock Whenever orders are exchanged between the communication module and the coupled lock The connection is checked by means of a polling procedure once per minute OUT3 Privacy mode active Is activat...

Page 19: ...odule are open collector outputs which can switch max 150mA The maximum voltage is 28V An open collector output is not a potential free contact The output consists of a transistor semiconductor which...

Page 20: ...back diode directly on the load The device may be damaged if no flyback diode has been used or if it was connected falsely Situation 2 Circuit with an input A Communication module B Device with an inp...

Page 21: ...pply unit fails the communication module can continue to work for some days with a new set of batteries 8 3 Battery warnings If the batteries of the communication module are nearly empty the communica...

Page 22: ...has to be switched on l Firmware has to be installed on the communication module see Firmware on page 27 1 Press the coupling button Now the red LED next to the coupling button indicates the battery s...

Page 23: ...dule and pull off the cover 2 If necessary take out the two empty batteries Insert the two new batteries Please ensure that the batteries are inserted according to the labelling in the battery compart...

Page 24: ...mpty to the communication module which then can be displayed by our third party device Only one lock one motor cylinder or door controller can be coupled to a communication module at the same time Pre...

Page 25: ...firmware update Otherwise no device can be coupled to the communication module 2 Press the coupling button of the communication module for approx 1 second If the communication module was able to coupl...

Page 26: ...er manual For the communication module By resetting the communication module see Reset of the communication module on the facing page 9 3 Coupling to a new lock You can couple the communication module...

Page 27: ...ways compatible with the firmware in the lock Firmware updates l The firmware is always automatically updated after a lock has been coupled to the module see How to couple a lock on page 24 Consequent...

Page 28: ...ommunication module back on by restoring the power supply with the power supply unit or by reinserting the batteries 4 Release the coupling button The coupled lock and the firmware have now been delet...

Page 29: ...of the nursing service can no longer open your lock However your children can still open the lock because they have received the key directly from you When in privacy mode the lock can still be opene...

Page 30: ...e g certain doors must not be locked When in night locking mode the motor prevents the knob from being manually turned by exerting force in the opposite direction This uses a lot of battery energy whi...

Page 31: ...rs 6 outputs with standard assignment Maximum load 28V 150 mA RF Transceiver RF Transceiver 868 MHz for wireless communication with compatible CESeasy devices Encryption AES128 Service life Battery se...

Page 32: ...12 2 Dimensions Page 32 of 37 CESeasy communication module 12 Technical data...

Page 33: ...contaminants contained in them can lead to health and environmental hazards In addition appropriate disposal allows recovery and re use of recyclable materials which is a substantial contribution to m...

Page 34: ...y Collection points for batteries and rechargeable batteries are identified by a variety of symbols Package Packaging of the components is made from environmentally friendly reusable materials In deta...

Page 35: ...sumption 21 Battery replacement 23 D Declaration of conformity 6 E EU Declaration of conformity 6 F Flyback diode 20 N Night locking 29 Night locking mode 29 Night locking mode ON OFF 29 P Privacy mod...

Page 36: ...S Safety instructions 6 Page 36 of 37 CESeasy communication module 14 Index...

Page 37: ...com CESfrance SARL 8 Impasse Charles Petit F 75011 Paris 33 1 44 87 07 56 33 1 43 07 35 78 infofr ces eu Austria C sar A C rcamo B ro Wiener Bundesstrasse 33 A 4050 Traun 43 660 73 20 311 43 732 21 0...

Reviews: