CES 4700VP Manual Download Page 17

CES SUPPORT 407-679-9440                                                           

Page 17

MAN71© CES 2010

7 = 200 ms

8 = 250 ms

9 = 300ms

Example:  To program the sampling window to 95ms enter the following sequence: 55# 3#   

Dialing mode (56#)

The method of dialing the phone line may be changed by using the 56# command. The choices available include 
regenerated DTMF or pulse dialing at the rate of 10 or 20 pulses per second. 

0 = DTMF

1 = Pulse (10 per second)

2 = Pulse (20 per seconds)

Example: To program DTMF dialing mode enter the following sequence: 56# 0#  

Ignore COR to Ring Out (57#)

When set to 0 (factory default) the 4700VP will not Ring Out if the channel is busy (COR LED On). If answering 
mode is set for COR only, this feature should be turned off.  When programmed to ignore COR, the 4700VP will 
ring out one time (if busy) alerting the mobile operator of an incoming call. 

0 = no

1 = yes

Example: To turn the ignore COR off, enter the following sequence: 57# 0#  

Answering a Call  (58#)

For more flexibility, the 4700VP can be programmed to answer a call in 4 different ways or can be programmed to 
ignore ring voltage for mobile initiated calls only.
0 = Ignore phone line

1 = Connect Code with COR

2 = Connect Code with COR & CTCSS

3 = COR & CTCSS

4 = COR only

Example: To program 4700VP to ignore the phone line ringing, enter the following sequence: 58# 0#  

Hook Flash Period (59#)

This feature is used in conjunction with 

call waiting

offered in some markets by the telephone company. This allows 

the mobile user to answer a second call without disconnecting call in progress. The user can 

flash

between calls by 

momentarily activating the star (*) key plus 2 digits. The 

flash 

time period is programmable from 200ms ~ 800ms 

or it may be turned off.

0 = off

1 = 200ms

2 = 250ms

3 = 300ms

4 = 350ms

5 = 400ms

6 = 450ms

7 = 500ms

8 = 550ms

9 = 800ms

Example: To enable  

hook flash

enter the following sequence: 59# 1#  

Connect / Access Code (60#)

Up to a 10 digit access code can be programmed in the model 4700VP (only characters 0 ~ 9 will be accepted, 3 or 
more digits recommended). With no multi-digit code programmed, the default code is a single star (*) and single 
pound (#) for disconnect.    

NOTE: The * will always proceed the connect code and the # will always proceed the 

disconnect code

Example: To program the 4700VP for a connect code of *123 enter the following sequence: 60# 123#

Toll Restrict Override Code (61#)

The Toll Restrict Override Code will give privileged users the ability to bypass the toll restriction table. The code 
can be programmed for up to 10 digits string. This code must be different from the Connect code and other control 
codes.

Summary of Contents for 4700VP

Page 1: ...Model 4700VP Versatile Telephone Interconnect CES Wireless Technologies 925 122 South Semoran Blvd Winter Park FL 32792 407 679 9440 MAN71 Version 1 6 Friday August 20 2010 Printed in USA...

Page 2: ...PARAMETERS EXPLAINED 12 Speed Dial Locations 01 through 25 12 Factory Defaults Settings 30 12 Lead in Delay 31 12 Mobile Activity Timer 32 13 Call Limit Timer 33 13 CWID Time Interval 34 13 Repeater...

Page 3: ...CES SUPPORT 407 679 9440 Page 3 MAN71 CES 2010 Last Number Re dial 0 19 4 1 CIRCUIT DIAGRAM 22 5 1 USER CODE CHART 23 6 2 AMENDMENTS ERROR BOOKMARK NOT DEFINED...

Page 4: ...actory freight prepaid only with prior authorization Please call 407 679 9440 for an RMA number A brief letter describing the nature of the defect should be included with the merchandise Repair by oth...

Page 5: ...ble in standard products Please call your CES Applications Engineer to discuss special applications to meet other needs Because we are engaged in a program of continual product development the specifi...

Page 6: ...luding User Programmable Toll Restriction with Allow Deny Table Toll Restriction Override Code User Programmable CWID User Programmable Connect Access code Local or Over the Air Programming 25 Speed D...

Page 7: ...driver Solder and Soldering Iron Service Monitor or Deviation Meter optional for transmitter deviation adjustments 1 8 flat blade adjustment tool or a jeweler s screwdriver Digital Multimeter recommen...

Page 8: ...CES SUPPORT 407 679 9440 Page 8 MAN71 CES 2010 2 5 Component Layout Fig 2 5 1 4700VP Component Layout...

Page 9: ...active low 5 Ground Power Connect to a suitable ground point in the radio 6 TX Audio Analog Connect to the microphone audio input of the transceiver transmitter 7 N C N A 8 External COR Digital Use t...

Page 10: ...udio is used for pin 2 then an additional wire called External COR pin 8 MUST BE CONNECTED This signal is a DC signal that changes in level when the squelch control of the radio is opened or CTCSS is...

Page 11: ...nitor to receive on the transmitter frequency 2 With the telephone line plugged into connector J1 press the front panel switch to manually connect A dial tone will be transmitted 3 Adjust R43 to 4 0 k...

Page 12: ...p Three 400 Hz tones generated rapidly e g 95 3 3 Programming Parameters Explained The following is a list of available programmable features Parameters in bold letters denote the factory default sett...

Page 13: ...nnel or when a call is in process This command is user programmable in ten steps 0 5 min 1 10 min 2 15 min 3 20 min 4 25 min 5 30 min 6 45 min 7 1 hr 8 1 5 hrs 9 2 hrs Example To program time period t...

Page 14: ...ow operation 0 active low 1 active high Example To program the CTCSS polarity for active high enter the following sequence 42 1 Gate COR with CTCSS 43 This code when enabled will look for a logic chan...

Page 15: ...nterval time disconnect connect disconnect interval time connect disconnect or it may be disabled The CW ID will not be transmitted if the system is busy 0 off 1 timer 2 connect 3 timer connect 4 disc...

Page 16: ...ery useful if the interconnected call is put on hold particularly on music on hold Factory default is 12 seconds and is user programmable up to 25 seconds or turned of 0 off 1 3 sec 2 4 sec 3 6 sec 4...

Page 17: ...4 COR only Example To program 4700VP to ignore the phone line ringing enter the following sequence 58 0 Hook Flash Period 59 This feature is used in conjunction with call waiting offered in some mark...

Page 18: ...speed dial locations to 1212 enter the following sequence 63 1212 CW ID Call Letters 64 Up to 15 characters can be programmed into the 4700VP as a station ID Each character is entered with a 2 digit c...

Page 19: ...e denied because a wild card did followed the 1800123 in the deny string 1 1800123 1800 Table 3 1 4 Summary of Programming Commands Code Function Factory Default 0 Last Number re dial N A 00 Exit Prog...

Page 20: ...Pulse Length 0 ms 60 Connect Access Code 61 Toll Restrict Override Code None 62 Remote Program Code None 63 Speed Dial Remote Program Code None 64 CWID Programming None 70 Toll Restriction Deny String...

Page 21: ...CES SUPPORT 407 679 9440 Page 21 MAN71 CES 2010...

Page 22: ...CES SUPPORT 407 679 9440 Page 22 MAN71 CES 2010 4 1 Circuit Diagram...

Page 23: ...peed Dial Location 11 connect code 11 Speed Dial Location 12 connect code 12 Speed Dial Location 13 connect code 13 Speed Dial Location 14 connect code 14 Speed Dial Location 15 connect code 15 Speed...

Reviews: