Repeat Mode Enable (46#)

This programming code enables the repeat mode. The repeat mode allows receive audio to be passed to a transmitter 
for mobile to mobile communications. This mode should only be enabled if the receiver and transmitter are 
independent of each other. This will not work on a Push to Talk/Release to Listen transceiver. 

0 = off

1 = on

Example: To enable the repeat audio function enter the following sequence: 46# 1#  

Roger Beep (47#)

The 4700 provides a short audible beep into the telephone line each time the mobile user un-keys. This gives an 
audible indication to the telephone party that they may now begin to talk.

0 = off

1 = On

Example : To enable courtesy beep function enter the following sequence: 47# 1#

Toll Restriction on speed dial location (48#)

Speed call locations can be toll restricted by enabling this command. When enabled, this will prevent dialing of 
digits entered in the toll restrict locations.
0 = no

1 = yes

Example: To disable this feature enter the following sequence: 48# 0#

CW ID Interval (49#)

The CW ID feature can be programmed to transmit the Station Identification at pre-programmed CWID Time 
Interval, connect, connect & interval time, disconnect, interval time & disconnect, connect /disconnect, interval time 
& connect / disconnect, or it may be disabled. The CW ID will not be transmitted if the system is busy.

0 = off

1 = timer

2 = connect

3 = timer & connect

4 = disconnect

5 = timer & disconnect

6 = connect/disconnect

7 = timer, connect/disconnect

Mode of Operation (50#)

The model 4700VP can operate in three different modes; Half Duplex, Simplex Sampling or Simplex with 

VeraTec™ 

Smart Sampling. 

Half Duplex

In Half Duplex the 4700VP will keep the transmitter keyed for the duration of the call. When programmed for half 
duplex operation it must be installed on a repeater or two radios using different frequencies.

Simplex Sampling

In the Simplex Sampling mode the 4700VP will sample at the programmed rate looking for a mobile carrier. If there 
is a carrier present it will stay in the receive mode until carrier goes away. If the carrier is not present, the 4700VP 
will go back to transmit mode until the next sample interval. 

Simplex with VeraTec™ Smart Sampling

In the Simplex mode with VeraTec™

(CES proprietary smart sampling protocol), the 4700VP mixes Vox and 

Sampling  modes. When audio is present on the telephone line, the 4700VP will operate in Vox mode until the 
maximum Vox timer ends. The maximum Vox timer controls how long the 4700VP will stay keyed continuously. 
The unit will then enter sampling mode allowing the mobile operator to take control of the unit. This feature is very 

Summary of Contents for 4700VP

Page 1: ...Model 4700VP Versatile Telephone Interconnect CES Wireless Technologies 925 122 South Semoran Blvd Winter Park FL 32792 407 679 9440 MAN71 Version 1 6 Friday August 20 2010 Printed in USA...

Page 2: ...PARAMETERS EXPLAINED 12 Speed Dial Locations 01 through 25 12 Factory Defaults Settings 30 12 Lead in Delay 31 12 Mobile Activity Timer 32 13 Call Limit Timer 33 13 CWID Time Interval 34 13 Repeater...

Page 3: ...CES SUPPORT 407 679 9440 Page 3 MAN71 CES 2010 Last Number Re dial 0 19 4 1 CIRCUIT DIAGRAM 22 5 1 USER CODE CHART 23 6 2 AMENDMENTS ERROR BOOKMARK NOT DEFINED...

Page 4: ...actory freight prepaid only with prior authorization Please call 407 679 9440 for an RMA number A brief letter describing the nature of the defect should be included with the merchandise Repair by oth...

Page 5: ...ble in standard products Please call your CES Applications Engineer to discuss special applications to meet other needs Because we are engaged in a program of continual product development the specifi...

Page 6: ...luding User Programmable Toll Restriction with Allow Deny Table Toll Restriction Override Code User Programmable CWID User Programmable Connect Access code Local or Over the Air Programming 25 Speed D...

Page 7: ...driver Solder and Soldering Iron Service Monitor or Deviation Meter optional for transmitter deviation adjustments 1 8 flat blade adjustment tool or a jeweler s screwdriver Digital Multimeter recommen...

Page 8: ...CES SUPPORT 407 679 9440 Page 8 MAN71 CES 2010 2 5 Component Layout Fig 2 5 1 4700VP Component Layout...

Page 9: ...active low 5 Ground Power Connect to a suitable ground point in the radio 6 TX Audio Analog Connect to the microphone audio input of the transceiver transmitter 7 N C N A 8 External COR Digital Use t...

Page 10: ...udio is used for pin 2 then an additional wire called External COR pin 8 MUST BE CONNECTED This signal is a DC signal that changes in level when the squelch control of the radio is opened or CTCSS is...

Page 11: ...nitor to receive on the transmitter frequency 2 With the telephone line plugged into connector J1 press the front panel switch to manually connect A dial tone will be transmitted 3 Adjust R43 to 4 0 k...

Page 12: ...p Three 400 Hz tones generated rapidly e g 95 3 3 Programming Parameters Explained The following is a list of available programmable features Parameters in bold letters denote the factory default sett...

Page 13: ...nnel or when a call is in process This command is user programmable in ten steps 0 5 min 1 10 min 2 15 min 3 20 min 4 25 min 5 30 min 6 45 min 7 1 hr 8 1 5 hrs 9 2 hrs Example To program time period t...

Page 14: ...ow operation 0 active low 1 active high Example To program the CTCSS polarity for active high enter the following sequence 42 1 Gate COR with CTCSS 43 This code when enabled will look for a logic chan...

Page 15: ...nterval time disconnect connect disconnect interval time connect disconnect or it may be disabled The CW ID will not be transmitted if the system is busy 0 off 1 timer 2 connect 3 timer connect 4 disc...

Page 16: ...ery useful if the interconnected call is put on hold particularly on music on hold Factory default is 12 seconds and is user programmable up to 25 seconds or turned of 0 off 1 3 sec 2 4 sec 3 6 sec 4...

Page 17: ...4 COR only Example To program 4700VP to ignore the phone line ringing enter the following sequence 58 0 Hook Flash Period 59 This feature is used in conjunction with call waiting offered in some mark...

Page 18: ...speed dial locations to 1212 enter the following sequence 63 1212 CW ID Call Letters 64 Up to 15 characters can be programmed into the 4700VP as a station ID Each character is entered with a 2 digit c...

Page 19: ...e denied because a wild card did followed the 1800123 in the deny string 1 1800123 1800 Table 3 1 4 Summary of Programming Commands Code Function Factory Default 0 Last Number re dial N A 00 Exit Prog...

Page 20: ...Pulse Length 0 ms 60 Connect Access Code 61 Toll Restrict Override Code None 62 Remote Program Code None 63 Speed Dial Remote Program Code None 64 CWID Programming None 70 Toll Restriction Deny String...

Page 21: ...CES SUPPORT 407 679 9440 Page 21 MAN71 CES 2010...

Page 22: ...CES SUPPORT 407 679 9440 Page 22 MAN71 CES 2010 4 1 Circuit Diagram...

Page 23: ...peed Dial Location 11 connect code 11 Speed Dial Location 12 connect code 12 Speed Dial Location 13 connect code 13 Speed Dial Location 14 connect code 14 Speed Dial Location 15 connect code 15 Speed...

Reviews: