900MHz and 2.4MHz Manual
2019 Cervis, Inc.
17
C3: BU-xH8D/MCB Remote Communication
Caution
To prevent inadvertent machine movement, be sure to
remove power from the base unit before attempting to
Associate or Dissociate.
To Associate (see Figure 10)
The MCB remote must be OFF and the base unit must have power removed before beginning the
Association process.
Note: The Machine Stop button must be in the UP position before activating and using the
mini console box remote.
1. Stand near the base unit with the remote
OFF
and
power removed
from the
base unit (disconnect P1 and P2 or turn the source power OFF).
2. Release the
STOP
button on the MCB handheld remote by pulling it up.
3. Push and hold switch
S1 UP
; then, press the
Power ON
button. All four LEDs
light solid.
4. Observe the LEDs. When the TX LED begins to blink, power up the base unit
while continuing to hold S1 and the Power button. When all four LEDs light solid,
release S1 and Power Button.
Association is successful when the TX and RX LEDs are rapidly flashing in unison.