Technical information

Winding

Quartz watches do not need to be wound.

PRECIDRIVE

PRECIDRIVE quartz chronographs, from CERTINA

®

, can boast not only the incomparable precision of quartz, but also their temperature variation compensated 

(thermo-compensated) rate, making them insensitive to moisture. This enables them to achieve a precision of /-10 seconds per year (under normal 
conditions of use).

Automatic calibration

The POWERDRIVE motors used to drive the hands ensure extremely precise and rapid movements. To ensure that they are working correctly, an automatic 
calibration is performed once an hour on both the central counter hands (

7

 and 

8

):

  –  One-step forward / backward movement
   or
  –  A complete dial rotation (alternating between the two hands)
These visible movements are part of the normal operation of the chronograph.

EOL (End of Life) function

When the seconds hand (

3

) is jumping every 4 seconds, your chronograph is telling you that the battery has reached its end of life, and will soon need to be 

replaced.

Care and maintenance

We would advise you to clean your chronograph regularly (except for the leather strap) using a soft cloth and lukewarm soapy water. After immersion in salt 
water, rinse it in fresh water and leave it to dry completely.
Do not leave it anywhere subjected to high variations in temperature or humidity, direct sunlight or strong magnetic fields. 
We would advise you to have your watch inspected every 3 to 4 years by an approved CERTINA

®

 representative or retailer. To enjoy impeccable maintenance 

service and ensure the guarantee remains valid, always consult an approved CERTINA

®

 representative or retailer.

If you plan not to wear your chronograph for several weeks or months, we would advise you to store it with the crown (

9

) pulled out to position 

III

. This cuts 

the electrical power supply to the motor, thereby extending battery life considerably.

Replacing the battery

The autonomy of a PRECIDRIVE chronograph from CERTINA

®

 is generally more than 2 years in continuous use. Once the battery has been drained, it must be 

replaced without delay by an approved CERTINA

®

 representative or retailer.

Battery type: 

silver oxide and zinc button cell, 1.55 V, No. 394, SR 936 SW.

Collection and treatment of end of life quartz watches*

 

This symbol indicates that this product should not be disposed of as household waste. It must be returned to an approved collection point. By following 
this procedure you will contribute to safeguarding the environment and human health. Recycling the materials will help to conserve natural resources.

 

* valid in EU member states and in any countries with corresponding legislation.

FLYBACK function

The 

FLYBACK

 function enables you to restart the chrono 

instantly, with the hands reset.

A

 START

B

 FLYBACK

A

B

C

I

A

B

C

I

Fig. 18

Fig. 19

Summary of Contents for PRECIDRIVE Flyback DS-2

Page 1: ... Hour hand Minute hand Seconds hand small seconds Date indicator Chronograph 12 hour counter hand 30 minute counter hand 60 second counter hand 60 second counter hand split second 3 position crown I Rest position screwed in not pulled out II Date setting position unscrewed half pulled out III Time setting position unscrewed completely pulled out A START STOP pusher B Flyback Reset pusher C Split s...

Page 2: ... in to ensure that your watch remains water resistant You are advised not to operate the crown 9 underwater Setting the time Pull the crown 9 out to position III the seconds hand 3 will stop and the chronograph counter hands 5 6 7 and 8 will complete a rotation of the dial entering setting mode Turn the crown 9 clockwise or anticlockwise to set the desired time and then push it back into the rest ...

Page 3: ...rotation of the dial entering setting mode Every time pusher A is pressed a hand will complete a rotation of the dial active hand and can be returned to its start point by repeatedly pressing pusher B Simple timing The simple timing function enables you to measure individual events A START A STOP Time readout as per Fig 3 1 hour 21 minutes 57 seconds B Reset NB Before each timing operation the chr...

Page 4: ...raph hands catch up to the ongoing elapsed time A START C STOP Split time 1 readout as per Fig 5 1 hour 22 minutes 57 seconds C RESTART catchup as per Fig 6 C STOP Split time 2 readout as per Fig 7 2 hours 5 minutes 20 seconds C RESTART catchup as per Fig 8 A STOP Final time readout as per Fig 9 3 hours 10 minutes 40 seconds B Reset the counters as per Fig 10 I A B C I A B C I A B C I A B C Fig 7 ...

Page 5: ...re superimposed A START C STOP Split time 1 readout as per Fig 12 1 hour 5 minutes 35 seconds C RESTART C STOP Split time 2 readout as per Fig 13 2 hours 10 minutes 10 seconds A STOP Final time readout as per Fig 14 3 hours 15 minutes 30 seconds C STOP Redisplay last memorised split time as per Fig 15 2 hours 10 minutes 10 seconds C STOP Redisplay memorised final time as per Fig 16 3 hours 15 minu...

Page 6: ...t leave it anywhere subjected to high variations in temperature or humidity direct sunlight or strong magnetic fields We would advise you to have your watch inspected every 3 to 4 years by an approved CERTINA representative or retailer To enjoy impeccable maintenance service and ensure the guarantee remains valid always consult an approved CERTINA representative or retailer If you plan not to wear...

Reviews: