48
ENGLISH
Operating Functions
Code
Description
Features
QPA5S11001CT PANEL CLASS PH 5-7 - RX 10-5 230V
Every time the device is started, the two tool pumps display the firmware version installed for a few
seconds.
Technical features of measurements:
P
H
Principle of measurement
Potentiometer
Measuring range
00.00 ÷ 14.00 pH
Resolution
± 0.01 Ph
Accuracy
± 0.2% F.s.
Repeatability
98%
Input impedance
> 10 GOhm
Polarisation
< 1 pA
REDOX
Principle of measurement
Potentiometer
Measuring range
0-2000mV
Resolution
± 1mV
Accuracy
± 0.2% F.s.
Repeatability
98%
Input impedance
> 10 GOhm
For further details, refer to the specific manual of the tool pumps installed on the panel
Overall dimensions
The overall dimensions of the panel are 450x600 (see Figure 4)