background image

Cermetek Microelectronics, Inc. 

High Speed Internet Modem Family 

 

 

2005 Cermetek Microelectronics, Inc. 

Page 14 

Document No. 607-0017 Revision I1 (05/05)

 

Figure 3.  PSTN Line Interface for all iNet Appliance Products.

 

 
 

1. Currently Limiting PSTN Protection Line 

Device. 

Currently limiting devices are mandatory to meet 
UL safety standards.  To maintain conveyed FCC 
Part 68 approval, the current limiting components 
identified as F1 and F2 in dashed Box #1 must 
also survive FCC Part 68 surge testing.  Refer to 
Cermetek Application Note #126, Supplemental 
PSTN Line Protection, for more details.  Refer to 
Application Note # 130, Summary of Recommend 
Suppliers, for a list of suppliers and associated 
part numbers. 
A.  A PTC (rated at 0.15 amps) is preferred 

because it resets automatically upon removal 
of the current flow.  Fuse devices are also 
acceptable.  Refer to Application Note #130 
for a complete list of recommended vendors 
and associated part numbers. 

B. Resistors (10

 carbon film or 1/8 watt 

minimum) may be used in Canada, as 
Canada has no requirements that PSTN 
equipment be operational after a Type B 
surge test. 

C.  Although CSA CS-03 Part 1 (Canada) follows 

the requirements of FCC Part 68 (USA), 
Cermetek recommends contacting DOT 
(Canada) and/or a certified independent lab to 
verify compliance.  For Canada, use either 
10

 resistors (carbon film or SMD parts 1/8 

watt minimum) as described in paragraph B 
above. 

2.  Over Voltage and Lightning Protection. 

A. Surge Protection is provided by internal 

circuitry (see Figure 3).  No additional external 
components are required to maintain 
conveyed FCC Part 68 approval. 

B. In most environments, 2 terminal surge 

suppressors are adequate.  For severe 
environments, use an external 3 terminal 
device with an earth ground. 

 

3. EMI/RFI 

Suppression. 

No external EMI/RFI noise suppression circuitry is 
required to maintain conveyed FCC Part 68 
approval.  However, additional suppression, if 
required for other reasons, may be added as 
described below in Sections 3A-3B without 
adversely affecting FCC Part 68 approval. 
A.  To provide adequate EMI/RFI suppression, 

the capacitor/inductor network contained in 
dashed Box #3 should be located as close to 
the RJ-11C jack as possible.  Further, this 
network should be provided with an excellent 
ground path to the chassis. 

B.  Capacitors C1 and C2 should not exceed 

0.005

µ

f.  They must have a rating of 1.5KV 

and typically are 0.001

µ

f ± 20%.  Inductors L1 

and L2 may be either individual inductors or a 
dual inductor.  Refer to Application Note #130 
for a complete list of recommended vendors 
and associated part numbers.  For UL 
applications, choose capacitors and inductors 
that are UL 1950 listed.  The actual values of 
the components used may vary depending on 
the end product design. 

 

Summary of Contents for CH2124

Page 1: ...d available free of change INTRODUCTION Direct machine to machine interaction represents the next logical extension of the internet Cermetek internet modem iModem products are designed to exploit the internet to facilitate the utilization of machine to machine interactions Using email information can easily be transferred between systems and can be transmitted retrieved at will Internet email prov...

Page 2: ...H2124 iModem contains a fully functional 56kbps 2400bps modem and the hardware and firmware needed to provide the internet capability Because of the unique architecture of Cermetek iModems these iModems have the ability to operate as either an internet email transceiver or as a high reliability analog modem Additionally the CH2124 60 products support user remote access which can be used to reprogr...

Page 3: ... the idle state if a low going TTL pulse is presented to the SEND Email Control Pin Pin 6 at any time during or after initiation of email send Semi Autonomous Control This method requires a minimal amount of host processor intervention and requires that the DTE serial port be operational Semi autonomous control is a special case of full Host Supervised Control and relies on the preprogrammed defau...

Page 4: ...nds an ASCII MESSAGE ACCEPTED activity response message and sends a TTL LOW Pulse to Pin 8 indicating that the ISP Mail Server has accepted the email message Control of the internet capabilities of the iModem can be either event driven or initiated and controlled by a system level host processor Refer to Table 3 for a complete set of pin descriptions When not utilized in the internet connectivity ...

Page 5: ...on with the internal µP controller Refer to Application Note 158 Cermetek iModem Caveats and Definitions for a more detailed discussion of this issue IMPORTANT NOTE Cermetek recommends a minimum of 50ms inter character delay when sending commands to the CH2124 60 iModem Failure to do so could result in unpredictable performance Refer to Cermetek s High Speed Modem and FAX Family product data sheet...

Page 6: ...ware versions 1 262 or greater T J 1 1 2 7 12 Establish email message type to be sent when iModem SEND pin is activated or the TD command issued J1 will select the User Defined message or by K8 parameter for firmware versions 1 262 or greater T K0 n 1 2 6 Select PAP Authentication Protocol n 01 allows PAP only DEFAULT n 7D allows CHAP or PAP CHAP NOT SUPPORTED T K1 n 1 2 6 Set the number of dial u...

Page 7: ...is currently limited to 125 ASCII characters Blanks or spaces are allowed and count as 1 character per each occurrence The entered message is stored in message memory location M1 T N1 n 1 2 Enter local access phone number for ISP n T OP1 n 1 2 Enter POP3 server IP HEXIDECIMAL address n T OS1 n 1 2 Enter SMTP server IP HEXIDECIMAL address n T PW n 1 2 Enter Dialup Password Maximum length is 15 alph...

Page 8: ...5 Parameter must be specified as one ASCII alphanumeric character 6 Parameter must be specified as two alphanumeric characters Use a leading 0 if necessary 7 Effective with iModem Firmware Revisions 1 262 or greater the TJ0 and TJ1 commands have been replaced with K8 parameter modifiable with the TK8 command 8 Dial up Unix Shell account access is NOT currently supported on the iModem Network ISP 9...

Page 9: ...curs after successful email transmission and after receipt of MESSAGE ACCEPT status from ISP SMTP mail server MESSAGE DELETED 1 Occurs after successful deletion of specified message number s NO CONNECT 1 Occurs when PSTN line is released after unsuccessful dialup and or unsuccessful ISP negotiation and or unsuccessful SMTP server negotiation NO DIALTONE 1 Occurs after unsuccessful dialup and iMode...

Page 10: ...y User Defined email message TN1 Display local access POP phone number TOP1 Display POP3 server IP address TOS1 Display SMTP server IP address TPW Display Dial up password TPM Display POP3 password TP1 Display ISP password TS1 Display email subject TU1 Display email recipient TO name Commands To Interrogate iModem Command Function TI Display iModem product type and firmware revision TV Displays IS...

Page 11: ...rovable for use by DOT to Industry Canada CS 03 Part I However per Canadian procedures approval can only be granted after the iModem has been installed into the end product Typically Canadian approval is obtained by submitting the final end product to an independent test house or consultant for evaluation The test house consultant then forwards the test results and applicable documents to the regu...

Page 12: ...o the users or the operation of the user s equipment the telephone company will give the user notice in writing to allow the users to make any changes necessary to maintain uninterrupted service In certain circumstances it may be necessary for the telephone company to request information from the users concerning the equipment which the user has connected to the telephone line Upon request of the ...

Page 13: ...nary 1 condition is indicated by a HIGH 11 RXD O RECEIVE DATA Serial Receive data output Received marking or a binary 1 condition is indicated by a HIGH 12 NC NO CONECTION 13 DTR I DATA TERMINAL READY INPUT Active LOW Switching off DTR can either return modem to command state disconnect phone call or reset modem DTR should be set LOW when not in use 14 DSR O DATA SET READY LOW indicates handshakin...

Page 14: ...o verify compliance For Canada use either 10Ω resistors carbon film or SMD parts 1 8 watt minimum as described in paragraph B above 2 Over Voltage and Lightning Protection A Surge Protection is provided by internal circuitry see Figure 3 No additional external components are required to maintain conveyed FCC Part 68 approval B In most environments 2 terminal surge suppressors are adequate For seve...

Page 15: ...roducts Model Summary of Features Operating Temperature CH2124 2 Input Sense Pins Send and Retrieve Emails Email Send Control Pin Full Function V 22bis 2400bps FCC Part 68 Approved UL1950 listed 0 C to 70 C CH2160 2 Input Sense Pins Send and Retrieve Email Email Send Control Pin Full Function V 90 56Kbps FCC Part 68 Approved UL 1950 listed 0 C to 70 C Figure 4 Example Circuit for illumination of E...

Page 16: ...nput Current RST 580 uA CP Capacitive Load TXD DTR RTS Capacitive Load RTS 10 8 pF pF Table 6B CH2160 iModem Electrical Specifications Symbol Characteristic Min Typ Max Units VCC Positive Supply Voltage 4 5 5 0 5 5 V ICC Off Hook Nominal Operating Current VCC 5 5V when modem is Off Hook 120 0 mA VIH High Level Input Voltage 5 0V 2 0 3 5 V VIL Low Level Input Voltage 5 0V 1 0 2 2 V VT Positive Hyst...

Page 17: ...lse 10 msec If user supplied Note 1 All CH2124 iModem devices perform an internal self check upon reset and will not respond to commands issued during this self check sequence Table 7B CH2160 iModem Electrical Specifications Parameter Minimum Typical Maximum Units Comments Off Hook Impedance 20 Mohm Trans Hybrid Loss 25 dB 600 Ohm RXA TXA Ring Voltage Loop 35 VPP On 48VDC line voltage for sustaine...

Page 18: ...e or for any infringements of patents or other rights of third parties resulting from its use No license is granted under any patents or patent rights of Cermetek Cermetek provides the user with a FCC USA and IC Canada Approved or Approvable device However Cermetek does not have influence over nor knowledge of the specific user application environment Therefore for FCC and IC Approved or Approvabl...

Reviews: