11.
Alarm Management and Troubleshooting
This section includes:
•
•
•
Viewing and Saving the Event Log
•
Editing Alarm Text and Severity and Disabling Alarms and Events
•
Configuring Voltage Alarm Thresholds
•
•
Notes:
CW mode, used to transmit a single or dual frequency tones for
debugging purposes, can be configured using the CLI. See
CW Mode (Single or Dual Tone) (CLI)
You can configure a wait time of up to 120 seconds after an alarm is
cleared in the system before the alarm is actually reported as being
cleared. This prevents traps flooding the NMS in the event that some
external condition causes the alarm to be raised and cleared
continuously. The timeout for trap generation can be configured via
CLI. See
Configuring a Timeout for Trap Generation (CLI)
11.1
Viewing Current Alarms
To display a list of current alarms in the unit:
1 Select
Faults > Current Alarms
. The Current Alarms page opens. The Current
Alarms page displays current alarms in the unit. Each row in the Current
Alarms table describes an alarm and provides basic information about the
alarm. For a description of the information provided in the Current Alarms
page, see
Figure 324: Current Alarms Page
2 To view more detailed information about an alarm, click + at the beginning of
the row or select the alarm and click
View
.