Configuring Voltage Alarm Thresholds
You can configure undervoltage and overvoltage alarm thresholds.
The default thresholds for IP-20C are:
•
Undervoltage Raise Threshold: 32V
•
Undervoltage Clear Threshold: 34V
•
Overvoltage Raise Threshold: 60V
•
Overvoltage Clear Threshold: 58V
The default thresholds for the other IP-20 all-outdoor products are:
•
Undervoltage Raise Threshold: 36V
•
Undervoltage Clear Threshold: 38V
•
Overvoltage Raise Threshold: 60V
•
Overvoltage Clear Threshold: 58V
These thresholds determine when the following alarms are raised and cleared:
•
Alarm #32000: Under voltage
•
Alarm #32001: Over voltage
To voltage alarm thresholds:
1 Select
Faults > Voltage Alarm Configuration
. The Voltage Alarm Configuration
page opens.
Figure 331: Voltage Alarm Configuration Page