3) The motor is provided with a thermal motor protector – a protective device that is
sensitive to temperature and current – that will prevent the temperature of the motor
windings from exceeding:
i) 125°C (257°F) when the motor is running at the maximum load at which it can
operate without causing the protector to cycle, and
ii) 150°C (302°F) with the rotor of the motor locked.
b) Under wire, unless its insulation is flame-retardant, such as neoprene- or thermoplastic-
insulated wires.
6.8 The barrier mentioned in 6.7 shall be horizontal, shall be located as illustrated in Figure 6.1, and shall
have an area in accordance with that illustration. Openings for drainage, ventilation, and the like, may be
employed in the barrier provided such openings would not permit molten metal, burning insulation, or the
like to fall on combustible material.
DECEMBER 17, 1998
HOUSEHOLD TRASH COMPACTORS - UL 1086
9
Summary of Contents for UL 1086
Page 1: ...UL 1086 ISBN 1 55989 928 X Household Trash Compactors ...
Page 2: ......
Page 6: ...JANUARY 6 2004 UL 1086 tr4 No Text on This Page ...
Page 8: ...JANUARY 6 2004 HOUSEHOLD TRASH COMPACTORS UL 1086 2 No Text on This Page ...
Page 11: ...DECEMBER 1 1999 HOUSEHOLD TRASH COMPACTORS UL 1086 3 No Text on This Page ...
Page 20: ...DECEMBER 17 1998 HOUSEHOLD TRASH COMPACTORS UL 1086 10B No Text on This Page ...
Page 32: ...JANUARY 6 2004 HOUSEHOLD TRASH COMPACTORS UL 1086 18B No Text on This Page ...
Page 36: ...DECEMBER 1 1999 HOUSEHOLD TRASH COMPACTORS UL 1086 20B No Text on This Page ...
Page 40: ...JANUARY 6 2004 HOUSEHOLD TRASH COMPACTORS UL 1086 22B No Text on This Page ...
Page 58: ...JANUARY 6 2004 HOUSEHOLD TRASH COMPACTORS UL 1086 38B No Text on This Page ...
Page 70: ...DECEMBER 1 1999 HOUSEHOLD TRASH COMPACTORS UL 1086 48B No Text on This Page ...
Page 76: ...JANUARY 6 2004 HOUSEHOLD TRASH COMPACTORS UL 1086 52B No Text on This Page ...
Page 82: ...JANUARY 6 2004 HOUSEHOLD TRASH COMPACTORS UL 1086 A2 No Text on This Page ...