Page 13
Installation and Operation Requirements - S250
ENGLISH
3.1.2
With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
USA
A
14" (356 mm)
14" (356 mm)
B
20" (508 mm)
20" (508 mm)
C
11" (279 mm)
11" (279 mm)
L
72" (1829 mm)
72" (1829 mm)
Ve
Ho
L
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
A
6" (152 mm)
6" (152 mm)
B
18" (457 mm)
18" (457 mm)
C
8" (203 mm)
8" (203 mm)
L
72" (1829 mm)
72" (1829 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
18
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
18" (457 mm)
D
9 ¼" (235 mm)
9 ¼" (235 mm)
E
26 ½" (673 mm)
26 ½" (673
mm)
E
23 ¾" (603 mm)
23 ¾" (603 mm)
F
18 ¼" (464 mm)
18 ¼" (464 mm)
F
14 ½" (368 mm)
14 ½" (368 mm)
18
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.