page 44
www.centsys.com
6.7.1. Four-wire safety beams
6.7.1.1. Mounting
1. Mark the inside garage door framing so that the bottom edge of the beam sits
125mm off the floor.
2.
Using a small angle bracket, fasten each beam to the wall so that they face each
other across the garage door (Refer to installation instructions for further
information).
6.7. Safety Beams
• The Photon or other four-wire safety beams may be connected to the
SDO4 SMART
• The installation of safety beams greatly enhances safety by constantly monitoring
for persons or objects which may pass within the path of the moving garage
door
• The
SDO4 SMART
will safety reverse if the safety beams become momentarily or
permanently interrupted during a closing cycle
• A pair of Photon SMART infrared beams can be added to the SDO4 installation without
running any wires, making it an easy and cost-effective solution that offers maximum
safety
OPERATOR INSTALLATION
SECTION 6
6.7.1.2. Connection
Follow the safety beam instructions and connect to the output terminals. Use the
normally-closed contacts of the beam to connect to input ‘SB’ on the
SDO4 SMART
.
Refer to Section 7 - “
Electrical setup of accessories
”.
The
SDO4 SMART
provides a 24V DC output and normally-closed input for
safety beams.
For aligning and testing the safety beams, please refer to the installation manual
supplied with the respective safety beams used.
6.8. Connecting to a Power Supply
• Plug the
SDO4 SMART
into a properly-earthed 220 to 240V AC power outlet
•
Ensure that no excess power cord hangs below the control box
FIGURE 79
SDO4 SMART
power cable
220 TO 240V AC Power outlet
on ceiling
Cable clips