5.1. General Considerations for the Installation
Always recommend the fitment of additional safety equipment such as safety edges
and safety beams, for additional protection against entrapment or other mechanical
risks.
Ensure that no pipes or electrical cables are in the way of the intended installation.
Install the garage operator only if:
• It will not pose a hazard to the public
•
The installation will meet all municipal and/or local authority requirements once
completed
•
The door mass and application is within the operator specifications
• There is a properly-earthed general purpose 220-240V AC power outlet that has been
installed by a qualified electrical contractor
•
All locks, ropes and / or securing mechanisms have been removed
• The ceiling structure is adequate enough to support the weight of the
SDO4 SMART
• The garage door is in good working order, meaning:
• it opens freely;
• it is well-balanced;
,
• it does not move on its own if left in any position for more than 100mm;
•
it can be installed to have sufficient clearance between moving parts when
opening or closing to reduce the risk of personal injury and / or entrapment
Any repairs to the garage door that need to be done due to any of the above
requirements not being in place, must be carried out by technically qualified
persons.
Attempting to repair the garage door without suitable technical
qualifications, may result in severe personal injury, death, and / or
property damage.
An improperly-balanced or malfunctioning garage door could cause
serious personal injury, death and / or property damage.
Have a qualified person check and, if required, make repairs to the
garage door before installing the
SDO4 SMART
.
PREPARATION OF SITE
SECTION 5
5. Preparation of Site