The Power unit will give an audible and visual alarm when either the clogging of the filter(s) causes the airflow to drop to the minimum design flow
rate or when the battery voltage drops to a level below which it could not safely power the Power unit. When either of these conditions occur a
frequently repeating audible bleep is emitted and in addition the yellow LED on the top of the Power unit flashes if the filter is clogged or the red
LED flashes if the battery is low.
When either alarm condition occurs during use the wearer should leave the contaminated area immediately and replace the filter or recharge the
battery accordingly.
When first turning the unit on the alarm will beep to indicate the correct functioning of the alarm system. If the beep stops after a few seconds the
airflow is sufficient to proceed with using the unit.

When Used With Full facemask. ( clockwise setting )

The Power unit is designed to exceed the requirements of EN12942 TM3 in that it will provide a minimum design flow rate of at 95 litres/min
when used with a full-face mask. for at least 4 hours under all conditions, assuming a fully charged battery at start. (Minimum design duration =
4 hours). Typical battery duration depends on a number of factors but is usually around 8 Hrs.

The Power unit will give an audible and visual alarm when the battery voltage drops to a level below which it could not safely power the unit.
When this condition occurs a frequently repeating audible bleep is emitted and in addition the Red LED on the top of the Power unit flashes.
When  the  alarm  condition  occurs  during  use  the  wearer  should  leave  the  contaminated  area  immediately  and  recharge  the  battery.  The
electronic clogged filter low flow alarm is 

not

 enabled on the full-face mask setting. An airflow indicator is provided with the unit, which can be

used to check the flow prior to the use of the unit.

To check the airflow for full facemasks ensure that the filter and battery are fitted and turn the power unit on. The head piece hose should not
be fitted. Insert the airflow indicator into the outlet of the power unit with the letters on the label upright (See diagram I on page 6) and the label
facing  toward  the  front  of  the  unit  (where  the  filter  is  fitted).  If  line  A  is  fully  visible  then  the  unit  has  sufficient  airflow.  If  line  A  is  not  visible
replace the filters. If you have both replaced the filter and fully charged the battery and line A is still not visible the unit and battery should be
returned to the supplier.

7.          POWER UNIT FITTING

Ensure that the Power unit, Filter(s),air supply hose and headgear are not damaged, and that the battery is securely located in the Power unit.
Push the hose connector into the Power Unit outlet and twist the outlet collar to lock.
Turn on the Power unit and put the belt round the waist joining the buckles at the front.

8.          HEADPIECE  FITTING

Refer to the separate instructions supplied with the headpiece for fitting and maintenance instructions.

9.         CLEANING, MAINTENANCE & STORAGE

Maintenance

Power unit - routine maintenance is limited to cleaning of the equipment and replacement of filters.

Cleaning

General - Avoid inhaling any dust during cleaning
Do not use abrasive cleaning agents or organic solvents to clean any surface.
To clean all external components wipe with a damp cloth dipped in warm soapy water. Dry with a soft, clean cloth.
Do not attempt to clean the filters, once fully loaded they must be replaced.
Do not immerse the power unit in water or allow water to enter the unit via the air outlet or inlet.

Storage

All equipment  should be stored in a clean dry atmosphere (R.H. < 90%) within the temperature range -5

°

C to +55

°

C in the packaging provided.

It should be protected from direct sunlight and any material known to damage plastics, e.g. petrol and solvent vapours. Equipment should be
transported in the original packaging. If stored correctly this equipment has a shelf life of 5 years.

Disposal

Contaminated filters/pre filters should be disposed of in accordance with local Health & Safety Legislation.

10.        WEEE

WEEE (Refers to Power unit, Battery and Charger ONLY)

THESE PRODUCTS SHOULD NOT BE DISPOSED OF IN GENERAL MUNICIPAL WASTE

1. 

The crossed-out wheeled bin symbol, with the solid bar, shown on this product, its packaging or instructions indicates that the product has
been  manufactured  after  13/8/05  and  is  subject  to  European  Community  directive  2002/96/EC,  issued  27/1/03,  on  correct  handling  of
Waste Electronic and Electrical Equipment (WEEE).

2. 

WEEE cannot be disposed of as municipal waste and must be collected and disposed of separately. Appropriate public or private waste
collection systems defined by national and local regulations should be used.

3. 

The  product  may  contain  substances  which  could  harm  the  environment  or  human  health  if  disposed  of  incorrectly.

Summary of Contents for MAGNUM P2

Page 1: ...ll begin with TM Filters should only be fitted to the power unit do not attempt to fit them directly to a hood or helmet 2 LIST OF PARTS AVAILABLE HEADPIECES APPROVALS SPECIFICATION NOMINAL AND ASSIGN...

Page 2: ...hargeable battery pack which requires charging before use Ensure you are using the correct charger for your battery pack See Section 2 Standard Charger M23P2 4BC or M23HD4BC When charging the battery...

Page 3: ...rs e g M23 A2B2 P3 1000ppm 100mg m3 Dust filters TH2P e g M23P2 5 N A 400mg m3 Dust filters TH3P TM3P e g M23P3 5 N A 200mg m3 5 2 MAGNUM 1000 2000 Power unit M23 1000 M23 2000 Pre filters General The...

Page 4: ...suring that it is properly snapped shut If a pre filter is not used the main filter should be changed immediately the clogged filter alarm sounds indicates or the air flow indicator indicates reduced...

Page 5: ...d filter medium Do not use filters after their expiry date Do not use filters with no or damaged filter seal caps 6 AIR FLOW INFORMATION AND WARNING DEVICES MAGNUM 1000 POWER UNIT The Power unit is de...

Page 6: ...rious conditions The Power unit will give an audible and visual alarm when either the clogging of the filter causes the airflow to drop to the minimum design flowrate or when the battery voltage drops...

Page 7: ...here the filter is fitted If line A is fully visible then the unit has sufficient airflow If line A is not visible replace the filters If you have both replaced the filter and fully charged the batter...

Page 8: ...without charge 11 SPARES Description Part Number Shower resistant plastic shroud for 8500 unit M23PS Comfort pad item 11 M23CP L Spare Standard Belt item 1 M23B Plastic Belt Wipe clean for decontamina...

Reviews: