Centurion MAGNUM P2 Quick Start Manual Download Page 2

                024-001-750  MOD 8     11/05/07                            Page 2 of 8                                POWER UNITS

Centurion Safety Products Ltd. Howlett Way, Thetford, Norfolk, IP24 1HZ, UK

Tel. 0044 (0)1842 754266   Fax. 0044 (0)1842 765590

Compatibility between Headpieces and Power Units:
Headpieces:

Power Units:

Description

Code

1000/2000

8500      

Rigid Polycarbonate Visor with Saronex Hood

M23RVSN

 

Flip up Polycarbonate Visor

M23FUVN

 

                

Helmet with Flip-up Polycarbonate Visor

                M23HFUV

 

High Temperature Helmet with Clear Triacetate Flip up Visor                M23HFUVHTT

 

 

High Temperature Helmet with Gold Polycarbonate Visor

                M23HFUVHTGP       

 

Automatic Welding Visor

M23AWSN

 

Fixed Shade Welding Visor

M23FSWN

 

Full Facemask with Twin Hose

M23FF

 x

Full Hood without airflow indicator

M23FH/8

 x

Half Suit without airflow indicator

M23HS/8

 x

               

Lightweight P3 Tyvek F

                                               M23LHF

               

3.

APPLICATIONS AND LIMITATIONS

When  used  with  filters  M23P3/5,  M23P2/5  or  M23P3SL/6  the  Magnum  respirator  will  offer  protection  against  dusts,  particles,  fumes  and  aerosols
(solid and liquid based) to the levels detailed.
No protection is given against gases or vapours.
The  Magnum  system  should  not  be  used  where  airborne  concentration  of  contaminant  exceeds  the  Assigned  Protection  Factor  (APF)    x    the
Occupational exposure limit (OEL)
The system is recommended for use in the temperature range +5

°

 to +35

°

C and in conditions where relative humidity does not exceed 90%.

Protection Factors

The efficiency of all types of respirators is classified by the protection factor rating system. There are two main classifications for protection factors,
these are:

Laboratory Protection Factor

  (also known as Nominal Protection Factor)

This is the minimum level of protection the equipment has  to  demonstrate  for  each  of  a  panel  of  test  subjects  under  laboratory  conditions  to  gain
approval to the appropriate class of the performance standard.

Assigned Protection Factor (APF)

BS4275 or EN 529 acknowledges that laboratory performance is not always achievable in real use.
These figures are taken from BS4275: 1997 and are the minimum level of protection which it is calculated 95% of wearers who are trained in the use
of  the  equipment  should  achieve  in  practice,  with  well-maintained  equipment.  These  figures  are  valid  for  use  in  the  UK  and  may  differ  in  other
countries.
For further information regarding protection factors please contact our technical advice service.

4.

PREPARATION FOR USE

Battery

The  power  unit  is  fitted  with  a  rechargeable  battery  pack,  which  requires  charging  before  use.  Ensure  you  are  using  the  correct  charger  for  your
battery pack (See Section 2).

Standard Charger (M23P2/4BC or M23HD4BC) –

When charging the battery connected to a Turbo unit the turbo unit must be turned off.
Plug the charger into an appropriate mains supply.  Connect the battery charger plug to the charger socket on the battery pack. The LED indicator
will light if the charging circuit is satisfactory.
Batteries are supplied in a discharged condition, and must initially be charged for 20 hours before use. Subsequent charges only require 16 hours.
IOvercharging the batteries may permanently damage them.

Intelligent Charger (M23UIC) – 

This charger will charge all Magnum battery packs and will operate on both UK and European Voltages.

To change the mains plug from European to UK and vice versa unplug charger from mains and push up switch marked “Open” in the direction of
the arrow the plug should then pop out. Insert the replacement plug into the charger pushing firmly until it “clicks home” Batteries may be charged
on or off the turbo unit.

Batteries must be charged indoors at an ambient of between 10ºC and 30ºC. Do not cover charger.

Important :

 In excessive cold or warm environments the recharging device may suppress the charging current to standby level so the battery will

be not be charged.  Never charge in a potentially explosive atmosphere.

To use :

 Plug the charger into the main power supply (100 – 240V AC – 50-60 HZ). When no battery is connected, the LED (Light emitting Diode)

indicators light on the front of the charger should not be lit.
When charging the battery connected to a Turbo unit the turbo unit must be turned off.
Plug the charging connector into the socket in the rear of the battery pack.
The RED LED indicator will flash for a few seconds indicating that the charger is checking the status  of  the  battery  pack.  The  RED  LED  should
then light continuously indicating that the battery is being charged.
When the  battery  is  fully  charged  the  RED  LED  will  go  out  and  the  GREEN  LED  will  indicate.  At  this  point  the  battery  will  be  in  “trickle  charge”
mode, this will maintain the battery’s charge. The battery can be left permanently connected, if desired, until required for use.

Note :

 A new battery, a battery stored for a very long period or a battery that has been run completely flat so that is deeply discharged* may not

function correctly.
If when starting to charge such a battery the RED LED continues flashing for more than 10 seconds the charger has detected either a very deeply
discharged battery or a faulty battery.

Summary of Contents for MAGNUM P2

Page 1: ...ll begin with TM Filters should only be fitted to the power unit do not attempt to fit them directly to a hood or helmet 2 LIST OF PARTS AVAILABLE HEADPIECES APPROVALS SPECIFICATION NOMINAL AND ASSIGN...

Page 2: ...hargeable battery pack which requires charging before use Ensure you are using the correct charger for your battery pack See Section 2 Standard Charger M23P2 4BC or M23HD4BC When charging the battery...

Page 3: ...rs e g M23 A2B2 P3 1000ppm 100mg m3 Dust filters TH2P e g M23P2 5 N A 400mg m3 Dust filters TH3P TM3P e g M23P3 5 N A 200mg m3 5 2 MAGNUM 1000 2000 Power unit M23 1000 M23 2000 Pre filters General The...

Page 4: ...suring that it is properly snapped shut If a pre filter is not used the main filter should be changed immediately the clogged filter alarm sounds indicates or the air flow indicator indicates reduced...

Page 5: ...d filter medium Do not use filters after their expiry date Do not use filters with no or damaged filter seal caps 6 AIR FLOW INFORMATION AND WARNING DEVICES MAGNUM 1000 POWER UNIT The Power unit is de...

Page 6: ...rious conditions The Power unit will give an audible and visual alarm when either the clogging of the filter causes the airflow to drop to the minimum design flowrate or when the battery voltage drops...

Page 7: ...here the filter is fitted If line A is fully visible then the unit has sufficient airflow If line A is not visible replace the filters If you have both replaced the filter and fully charged the batter...

Page 8: ...without charge 11 SPARES Description Part Number Shower resistant plastic shroud for 8500 unit M23PS Comfort pad item 11 M23CP L Spare Standard Belt item 1 M23B Plastic Belt Wipe clean for decontamina...