18
19
Analogue modem
KomBoar
d2
1.
2.
GSM modem
3.
NOTEbefore installing a modem, read the user manual.
Page 1: ...Short Manual Powerstocc Excellent PS DC Storage www centrosolar com...
Page 2: ...verters Part 1 EN 62109 2 2011 safety of power converters Part 2 EU Declaration of conformity Directive 2004 108 EC Electromagnetic compatibility Directive 2006 95 EC Electrical Apparatus Low Voltage...
Page 3: ...usion of liability Any use that differs from or goes beyond the stated intended purpose is con sidered inappropriate The manufacturer accepts no liability for any damage resulting from this Modificati...
Page 4: ...mber 4 MPP control range 5 Maximum input voltage DC 6 Maximum DC input current 7 Number of feed in phases Output voltage nominal 8 Maximum AC power 9 Maximum output current AC 10 Deviating output with...
Page 5: ...C Air humidity must be between 0 and 95 non condensing Selecting the installation side NOTE Observe the following instructions or else warranty claims will be restricted Select stable installation loc...
Page 6: ...10 11 10 11 Installation 200 200 100 100 45 20 74 45 max 10 To lift the inverter 2 3 1 Cooling space Mounting spaces Powerstocc DC Storage Lift here Lift here...
Page 7: ...ne napetosti Nebezpe enstvo ohrozenia ivota z sahom elektrick ho pr du Meni prepnite do beznap ovej prev dzky Elektrik arpmas nedeniyle hayati tehlike nvert r gerilimsiz hale getirin Livsfara p grund...
Page 8: ...14 15 14 15 Connecting AC and DC side Connecting AC side Connecting DC side 1 2 Connecting main cable with sealing cap Second ground connection Country specific installation L1 L2 L3 N PE 3 Nm...
Page 9: ...DC1 DC2 in parallel DC1 DC2 Note When using the parallel connection this feature must be acti vated under the menue Settings Hardware settings String connection Parallel connection Data transfer Comm...
Page 10: ...18 19 18 19 Analogue modem KomBoard2 1 2 GSM modem KomBoard2 1 2 3 Note Before installing a modem read the user manual...
Page 11: ...OFF ON 1 2 3 ON 5 Nm Selecting the country of use Note Country setting DE may only be used with inverters installed in PV plants connected to the grid before 31 12 2011 No displacement factor cos pres...
Page 12: ...ES 4 H Enter Menu overview DC and AC DC menu Settings menu AC menu Battery menu Own consumption menu DC menu AC menu DC input 1 U I P DC input 2 U I P Phase 1 U I P Phase 2 U I P Phase 3 U I P Total y...
Page 13: ...settings 1 Auto IP Network settings 2 IP address Subnet mask Router settings External router Router IP RS485 settings Bus termination Bus bias voltage RS485 address Portal configuration Portal code D...
Page 14: ...Temperature C Charge cycles Menu Consumption Daily own consumption Own consumption Wh Own consumptions rate Autonomy degree Total own consumption Own consumption Wh Own consumptions rate Autonomy deg...
Page 15: ...V 314 Min battery input voltage V 211 Rated voltage battery input V 228 Max charge current A 12 Max discharge current A 12 Powerstocc DC Storage Unit Output side AC Rated output cos j 1 Pac r kW 10 M...
Page 16: ...e Unit System data Topology without galvanic separation transformerless H Internal protection according to IEC 60529 IP 55 Protection class according to IEC 62103 I Overvoltage category according to I...
Page 17: ...ltaic modules Made in Germany which are produced in the company s own production Sonnenstromfabrik in Wismar with the highest quality standards The company s product range includes crystalline high pe...