6
SE45010UMC.0306
4. Operating Procedures
(1) Connect the RF cable between main unit and hand unit.
(2) Turn the power switch on.
(3) Place tubing in sealing head.
(4) Pull the trigger lever. Watch that amber light turns on at sealing head.
(5) After amber light turns off, wait for a while (approximately one second or more),
and then release the lever.
(6) Remove tubing and inspect it.
5. Maintenance
5-1. Troubleshooting
The following table covers common problems and suggested solution. Other problems
should be corrected by authorized service personnel.
Symptom Likely
Cause
Solution
Power cord connection
Check power cord connection and
push it securely into machine and
wall socket.
Blown fuse
Check the fuse and replace, if
necessary. Refer to Section 5-2.
Switch is on, but the
POWER
lamp doesn’t
illuminate.
Equipment malfunction
Ask for repair service.
Sealed shape is bad.
Dirty clamp or sealing
head
Clean sealing head and clamp area.
Refer to Section 5-3.
Sealing clamp doesn't
move smooth.
Dirty clamp or sealing
head
Clean sealing head and clamp area.
Refer to Section 5-3.
Arc appears.
Wet or dirty sealing head Clean sealing head, dry thoroughly.
Refer to Section 5-3.