Centrometal CentroPelet ZV 20 Technical Instructions Download Page 14

GB

The heating timer-thermostat function is used to program the pellet boiler stove to automatically turn on and off within 
a period of one week.
To access programming, hold down button 

 for around three seconds, “

U T 0 1

” will be shown on the upper display: 

by pressing button 

 several times and referring to the table below, the stove can be programmed according to your 

needs. Press button   to exit the programming phase at any time.
These are the heating timer-thermostat parameters:

Parameter

Description

Programmable 

values

UT01

OFF; Day 1, ...,Day7

H.  timer-thermostat  ena-

bling and disabling. Day of 

the week setting

UT02

From 00 a 23

Current hour setting

UT03

From 00 a 60

Current minutes setting

UT04

Reserved

Technical parameters

setting

UT05

From 00:00 to 23:50 with 

10-minute steps

Thermostove first start-up 

time adjustment

UT06

From 00:00 to 23:50 with 

10-minute steps

Thermostove first 

shutdown time adjustment

UT07

Between on/off for days 

from 1 to 7

Week day selection, first 

time activation

UT08

From 00:00 to 23:50 with 

10-minute steps

Thermostove second

start-up time adjustment

Water Characteristics

The characteristics of the water used to fill the system are 
very important to prevent the build-up of mineral salts and 
the formation of incrustations along the pipes, in the boiler 
and in the heat exchangers. 
Therefore, please get your plumber’s advice  concering: 
• Hardness of water circulating in the system, to prevent
problems of incrustation and limescale, especially in 
the domestic water heat exchanger (>25° ).
• Installation of a water softener (if water hardness > 25°
).
• Filling the system with treated water (demineralised).

If you have very extensive system, with a large amount of 
water, or which require frequent refilling, it is recommended 
the  installation  of  water  softening  system.  It  ‘should 
be  noted  that  the  encrustations  drastically  reduce 
performance because of their low thermal conductivity.

Heating timer-thermostat

UT09

From 00:00 to 23:50 with 

10-minute steps

Thermostove second

shutdown time adjustment

UT10

Between on/off for days 

from 1 to 7

Week day selection,

second time activation

UT11

From 00:00 to 23:50 with 

10-minute step

Thermostove third start-up 

time adjustment

UT12

From 00:00 to 23:50 with 

10-minute step

Thermostove third

shutdown time adjustment

UT13

Between on/off for days 

from 1 to 7

Week day selection, third 

time activation

UT14

From 00:00 to 23:50 with 

10-minute steps

Thermostove fourth start-

up time adjustment

UT15

From 00:00 to 23:50 with 

10-minute steps

Thermostove fourth

shutdown time adjustment

UT16

Between on/off for days 

from 1 to 7

Week day selection, fourth 

time activation

Parameter

Description

Programmable 

values

Summary of Contents for CentroPelet ZV 20

Page 1: ...QUE CentroPelet ZV 20 24 32 TURZV 08 2014 HR Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TECHNICAL INSTRUCTIONS for installation use and maintenance of pell...

Page 2: ...Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly must be performed by authorized persons Authorized Assist...

Page 3: ...ivil and penal for accidents deriving from the partial or total lack of observance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from inc...

Page 4: ...y clothes hangers and suchlike must be kept a suitable distance from the stove Risk of fire Carefully explain that the thermostove is made from ma terial subjected to high temperatures for the elderly...

Page 5: ...able maintain a minimum distance of 10 cm at the rear A di 40 cm at the side B and 150 cm at the front If the room contains objects which are believed to be particularly delicate such as drapes sofas...

Page 6: ...less steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue pi...

Page 7: ...st be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself Fig 5 Characteristics of...

Page 8: ...s a lever to lift the cover Replace the battery observing the correct polarity Fig 4 Size 12V Fig 3 Fig 4 Size 12V Technical Specification Remote Control N B measures with a tolerance of about 10 mm 1...

Page 9: ...to 1 The LED is on when the parameter UT01 on the menu is not on OFF and the weekly or daily programming are set SET LED SYMBOL DESCRIPTION The LED starts up every time the stove is loading pellets T...

Page 10: ...To set the water temperature press the key only once You will see the words Set H2o blinking on the upper display You will read the water temperature on the lower display To set the room temperature p...

Page 11: ...control panel for example 18 C and a sufficient shut down time has elapsed the thermostove will come back on automatically and continue running until again reaching 20 C Regardless of the operation o...

Page 12: ...ety and can make it back in the system through the inlet pipe causing a phenomenon of oxygen that is highly damaging to life of the boiler To prevent this phenomenon it is possible to apply the follow...

Page 13: ...en it requires routine and or special maintenance Connect the stove using hoses so that the stove is not too strictly connected to the system and to allow slighht movement The filling pressure of the...

Page 14: ...ormation of incrustations along the pipes in the boiler and in the heat exchangers Therefore please get your plumber s advice concering Hardness of water circulating in the system to prevent problems...

Page 15: ...Friday Day 6 Saturday Day 7 Sunday OFF Heating timer thermostat disabled UT07 Week day selection Press button o select the days of the week Press button to enable ON or disable OFF the pellet boiler s...

Page 16: ...er fuses to protect the electronic boards are to be found on the boards themselves Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel an...

Page 17: ...sensor Check the water sensor is connected Contact an Authorized Assistance Center ALAR ALAR ALAR ALAR ALAR ALAR COOL ALAR ALAR ALAR ALAR SERV Hot temp The smokes temperature exceeds 280 C Smokes sens...

Page 18: ...he tank or because the motor reducer for pellets loading got broken The thermostove continues working until the pellets left in the brazier ends You will then read the words Alar No Fire on the displa...

Page 19: ...ould be no residual combustion in the contact zone between the edges of the crucible and the support surface on the door crucible Parts Everyday Every 2 3 days Every week Every 15 days Every 30 days E...

Page 20: ...tion Check every 60 90 days Cleaning the interior baffle smoke fan compartment Inside the compartment where there is the ash tray there is a second cover fixed by the cockerels which gives access to t...

Page 21: ...e there is a fuse holding compartment which is located underneath the supply socket With a screwdriver open the cover of the fuse holding compartment and replace the fuse if necessary 3 15 AT delayed...

Page 22: ...icular Do not touch the thermostove body and the various components do not approach the door it could cause burns Do not touch the exhaust fumes Do not perform any type of cleaning Do not dump the ash...

Page 23: ...r non original The operations marked in bold type must be carried out by specialised personnel Any kind of tampering or unauthorized substitution of non original of the thermostove can be hazardous to...

Page 24: ...not closed properly or gaskets worn 5 Boiler temperature is too high 6 Unsuitable pellets 7 Low pellet feed rate 8 Combustion chamber dirty 9 Smoke outlet obstructed 10 Smoke extraction motor failed...

Page 25: ...fan convention never stops 1 Temperature sensor temperature control defective or broken 2 Fan failure 1 Check operation of the sensor and replace if necessary 2 Check operation of the motor and repla...

Page 26: ...gh 2 It was set too much power to the implant 1 Lower the temperature in the boiler 2 Reduce the value of operating power The thermostove goes into modulation as it reaches the temperature set on the...