3.3 How to use and activate the Toucan Eco Ⅲ Unit

1

2

6

5

7

3

4

Fill the jug with tap water to the 1 litre mark. The water should be between 5 to 35⁰ C, 

and do not use purified water

Add 2g of table salt - that’s a flat measure using the short measuring spoon provided. No 

more or less as this affects the electrolysis. If too much salt is added, rinse out the jug 

and start again. Do not use rock salt.

Stir the solution with the long spoon at least 8 times in the centre of the jug to fully 

dissolve the salt. The salt acts as an electrolyte and if it accumulates on the electrode the 

product will not work. Place the lid on the jug, and wipe any water away from the 

electrodes on the bottom of the jug.

Connect the adapter to the base unit, plug into a wall socket and turn the power on at 

the wall. The base will beep and light flash twice.

Place the jug on its base. The base will beep once and the white button will remain lit. 

Activate the solution by pressing the button once. After 3 seconds the base light will flash 

and beep, the jug will light up blue and microbubbles appear as electrolysis begins.

After 5 minutes the base beeps, blue jug and white button lights stay on, and solution 

stops bubbling. It’s now ready to use and pour into the bottle. After 3 minutes you can 

activate again, indicated by a beep and lights switching off. This prevents the device from 

overheating.

Use the solution to safely spray, wipe or mop any surface clean and germ free. It can also 

be used as a deodoriser by killing the germs that creates the smell.

NOTE: For IMPORTANT information regarding correct usage - see 

Section 5

Summary of Contents for TOUCAN ECO III

Page 1: ......

Page 2: ...ed With The Unit Uses Use Usage How To Use and Activate the Toucan III Unit Safety Instructions Caution Use Only As Directed Directions for Safe Use Water quality Important Information Section Important infomation Trouble shooting Section Product Maintenance Maintenance of the body Drying and storage Cleaning the inside of the device Warranty Product Specification Product Accreditations Certified ...

Page 3: ...ruction manual carefully and keep it for future reference These instructions will show you how to use the Toucan Eco III unit safely and protect you from danger or damaging the unit Notice for customers in the countries applying EU or EPA Directives This product has been tested and found compliant with the limits set out in the EMC and EPA Directive and is fully CE compliant ...

Page 4: ...poon 2gm Portable Spray Bottle Salt additive Starter Kit Long spoon for mixing additives Spray Dispenser Fine mist spray delivers excellent coverage for a multitude of surfaces Propellant free Continuous spray large areas are covered quickly and evenly The following images of the product might be slightly different from the one supplied 10 10 SALT Lid Jug Electrode Base Button Spray Adapter Salt S...

Page 5: ...safe to use non toxic non hazardous non allergenic Toucan Eco III disinfectant is generated from natural salt dissolved in tap water and activated in the Toucan Eco III unit through Electro Chemical Activation You can make 1000ml of high level Hypochlorous containing solution in 5 minutes using just 2 grams of salt Activation generates solutions with hypochlorous acid active substance for easy hom...

Page 6: ...onnect the adapter to the base unit plug into a wall socket and turn the power on at the wall The base will beep and light flash twice Place the jug on its base The base will beep once and the white button will remain lit Activate the solution by pressing the button once After 3 seconds the base light will flash and beep the jug will light up blue and microbubbles appear as electrolysis begins Aft...

Page 7: ...r to fill the bottle or jug Use water of temperature ranges from 5 to 40 Use only 2 grams of salt in 1 litre of water This is 1 level measuring spoon Dissolve salt in the water by mixing thoroughly DO NOT add too much additive salt the device will automatically stop if excessive salt is used DO NOT use in an enclosed space Use only in a well ventilated area DO NOT swallow the activated solution If...

Page 8: ... continuously the device can stop because its adaptor is overheated and a thermal shutdown circuit is activated automatically In this case the unit will not work even when the button is pressed Separate the adaptor jack from the body cool down the adaptor at least 20 minutes and reconnect It will then work again Excessive use of the device more than 5 times continuously can cause failure of the pr...

Page 9: ......

Page 10: ...Section 7 0 Product Maintenance ...

Page 11: ...ize 130 x 130 x 280 mm Capacity maximum 1000ml Power Consumption 27W Material ABS PP IR In partnership with Ecowell Appearance of the product Slight acidic Hypochlorous acid HOCl 50 200ppm FAC with pH7 0 pH8 2 8 2 Accreditations EN 1276 EN 13624 EN 13697 EN 13727 EN 1656 8 3 Certified VAH Certified BAUA Registration EPA Approved CE NF T 72 281 EU Biocides Regulations No 528 2012 Article 95 listed ...

Page 12: ...Centrego Limited Unit N4 Marshall Way Frome Somerset BA11 3RG United Kingdom Tel 44 0 1373 470638 23 06 20 ...